
8
11/2018
STEP 6 - MOTORIZED OPERATOR (OPTION)
6.1
Traversing speed is fixed and not adjustable.
6.2
Always verify:
• Incoming power phases are wired correctly
• Motor turns in correct direction
• Limit switches stop motor
It may be necessary to swap two legs of wiring if motor runs in reverse.
6.3
Install breather on reducer (
diagram
6A
).
6.4
Reducer comes filled with oil from
factory which should not need to be
changed over the life of the unit. In the
event of spillage or other condition
where addition of oil is necessary,
use synthetic gear oil, ISO 320 grade
(Mobil Glygoyle 30 or similar).
6.5
Lubricate ball screw periodically (once per year or
every 10,000 actuations) (
diagram 6B
).
6.6
Limit switches and end stops are set at the factory.
Some field adjustment may be required for proper
rail alignment. See Step 6.7 on page 9 for
instructions.
WARNING
Running motor in reverse direction may cause permanent damage to clutch/motor/controls, therefore
voiding warranty.
Diagram 6A.
Installing breather on top of reducer.
Diagram 6B.
Ball screw location.
Summary of Contents for Tarca I Series
Page 2: ...11 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 4: ...11 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 15: ...11 11 2018 APPENDIX A BEAM END PREP DIAGRAMS...
Page 16: ...APPENDIX A BEAM END PREP DIAGRAMS CONTINUED 12 11 2018...
Page 17: ...13 11 2018 APPENDIX A BEAM END PREP DIAGRAMS CONTINUED...
Page 18: ...APPENDIX A BEAM END PREP DIAGRAMS CONTINUED 14 11 2018...
Page 19: ...15 11 2018 APPENDIX B WIRING DIAGRAMS 2 Way Motorized Schematic...
Page 20: ...APPENDIX B WIRING DIAGRAMS CONTINUED 16 11 2018 3 Way Motorized Schematic...
Page 21: ...17 11 2018 APPENDIX B WIRING DIAGRAMS CONTINUED 2 Way Pneumatic Schematic...
Page 22: ...APPENDIX B WIRING DIAGRAMS CONTINUED 18 11 2018 3 Way Pneumatic Schematic...