STEP 5 - CONTROL ENCLOSURE (OPTION)
Note:
208/230 VAC 3 phase 60 Hz or 460, 575 VAC 3 phase 60 Hz offered as standard. Control
voltage is 120 VAC, if supplied by Gorbel. Controls are factory set. Do not adjust without consult-
ing factory.
5.1
Refer to wiring diagrams. See Appendix B on pages 15-18.
5.2
Punch/drill enclosure and wire per code. If SAFPOWRBAR® is used, power for the controls
can be tapped off jumper harness.
5.3
Refer to appropriate wiring diagram in appendix for operator interface to control panel. Wall
mounted pendant option is available upon request.