background image

User Manual V1.0-2022-02-18

01

01 Safety Precaution

01    Safety Precaution

DANGER

• 

Please  keep  Power  Off  before  any  operations  to  avoid  danger.  Strictly  follow  all  safety 

precautions outlined in this manual and safety labels on the equipment.

•  All installation operations should be performed by trained and knowledgeable technical 

personnel who are familiar with local standards and electric systems. Learn about the 

product before installation.

•  Do not use the battery or the power control unit if it is defective, broken, or damaged.

•  Do not disassemble, modify, or replace any part of the battery or the power control unit 

without official authorization from the manufacturer.

•  Damaged battery may leak electrolyte. Do not contact with the liquid leakage or volatile 

matter. Please contact  After-sales Service for help immediately.

WARNING

Anyone contact the leaked substance accidentally has to do as following:

• 

Breath  in  the  leaked  substance:  Evacuate  from  the  polluted  area,  and  seek  immediate 

medical assistance.

• 

Eye contact: Rinse your eyes for at least 15 minutes with clean water and seek immediate 

medical assistance.

•  Skin contact: Thoroughly wash the touch area with soap and clean water, and seek immediate 

medical assistance.

•  Ingestion: Induce vomiting, and seek immediate medical assistance.

•  Do not move the  battery system if it is connected with external battery expansion modules. 

Please contact After-sales Service to replace batteries or add batteries.

CAUTION

Transportation:

•  Protect the battery system from damage during transportation and storage.

•  Take the weight of the battery and the power control unit into account and carefully lift the 

battery and the power control unit.

•  Wear gloves when handling the battery.

•  Do not hit, pull, drag, or step on the battery system or put unrelated items into any part of 

the battery system.

•  The transportation must be carried out by trained professionals. All operations during the 

process have to be recorded.

•  Keep the equipment stable to avoid dumping, which can result in equipment damage and 

personal injuries.

• 

In the event of a fire, please make sure that the carbon dioxide extinguisher or Novac1230 

or FM-200 is nearby.

• 

The fire cannot be put out by water or ABC dry powder extinguisher. Firefighters are required 

to wear full protective clothing and self-contained breathing apparatus.

• 

The battery may explode when the ambient temperature exceeds 150℃.

•  Please use appropriate tools and take protective measures when installing and maintaining 

heavy equipment. Improper operations will cause personal injuries.

•  Use professional insulating tools when operating the equipment under high voltage.

•  Place the cables at lease 30mm away from the heating components or heat sources, 

otherwise the insulation layer of the cables may be aging or broken due to high 

temperature.

• 

Tie the cables of the same type together, and place cables of different types at leas 30mm 

apart. Do not place the cables entangled or crossed.

Summary of Contents for Lynx Home F Series

Page 1: ...Lynx Home F Series HV V 1 2 2022 02 18 User Manual...

Page 2: ...ce notice The manufacturer shall not be responsible for any loss caused by this document including but not limited to omission errors typographical errors arithmetical errors or listing errors in this...

Page 3: ...6 05 System Installation 08 5 1 Installation Environment 08 5 2 Space Requirements 08 5 3 Battery System Installation 09 5 4 Electrical Connection 12 5 4 1 Connecting the PE Cable 12 5 4 2 Connecting...

Page 4: ...ules Please contact After sales Service to replace batteries or add batteries CAUTION Transportation Protect the battery system from damage during transportation and storage Take the weight of the bat...

Page 5: ...compatibility Directive 2014 30 EU EMC Electrical Apparatus Low Voltage Directive 2014 35 EU LVD Restrictions of Hazardous Substances Directive 2011 65 EU and EU 2015 863 RoHS Waste Electrical and El...

Page 6: ...right place and recycle it in compliance with local environmental regulations Pay attention to safety protection during installation CE Mark RCM Mark Grounding To indicate PE cable connection position...

Page 7: ...No Parts 1 Rectangular Connector 2 Grounding Point 3 1 Battery System Introduction 3 2 Battery Introduction 3 3 Base Introduction Notice Ensure that the PCU is installed above the Battery Module Do n...

Page 8: ...wer Control Unit Introduction No Parts 1 Positive Pole of Power 2 Negative Pole of Power 3 Ventilation Valve 4 COM Cable Port 5 Grounding Point 6 Circuit Breaker 7 SOC Indicator 8 Button Indicator 9 R...

Page 9: ...orage humidity 0 90 RH no condensation Do not install the battery if there is any moisture or condensation Place the equipment in a cool place where away from direct sunlight Keep the equipment away f...

Page 10: ...Module x1 Power Control Unit PCU x1 Base x1 Expansion Bolts x4 Red Power Connector x1 Black Power Connector x1 Terminal Resistor x 1 M5 12 Screw x4 Grounding Terminal x2 Locking Bracket x4 User Manua...

Page 11: ...ure for the Battery System is 20 40 Avoid exposing the equipment to direct sunlight or rain Install the equipment away from heat cold source Do not install the equipment in a place where the temperatu...

Page 12: ...Step1 Take the Battery Module the Base and the PCU out Step2 Install the locking bracket to the base Step3 Place the base cling to the wall and mark the drilling positions Then move the base Step4 Dri...

Page 13: ...05 System Installation 10 User Manual V1 0 2022 02 18...

Page 14: ...Manual V1 0 2022 02 18 Notice Shelter the equipment using paperboards when drilling to avoid dust Put the locking bracket cling to the wall And the bracket bottom cling to the Battery Module Watch ou...

Page 15: ...of the cable after crimping should be at least 400N Connect the PE cable to the PCU or to the base in the same way Notice Power off the Battery System before connecting the power cable to avoid high...

Page 16: ...ble conductor 16mm2 AWG 6 The strip length of the conductor 18 1mm The drawing force of the cable after crimping should be at least 1200N Make sure that the striped conductor is fine and has no burrs...

Page 17: ...ea of the power cable conductor 6mm2 AWG 10 The strip length of the conductor 33 1mm The drawing force of the cable after crimping should be at least 500N Make sure that the striped conductor is fine...

Page 18: ...the two communication ports And connect the terminal resistor to the other port For the EHB series and GE series inverters the manufacturer does not supply the battery communication cable Please refer...

Page 19: ...f the terminal resistor is not installed the Interlock Failure will occur and the system cannot work correctly Step1 Disassemble the waterproof module Step2 Install the terminal resistor Step3 Tighten...

Page 20: ...operate 2 The PE cable power cable communication cable and terminal resistance are connected correctly and securely 3 Cable ties are routed properly and evenly and no burrs 4 Unused ports and termina...

Page 21: ...ion Set battery model via PV Master App 6 3 Battery Parameters Download and install PV Master Connect your smart phone and the inverter Wi Fi SSID Solar WiFi Password 12345678 GoodWe BYD PYLON LG Alpa...

Page 22: ...arming or Faulty Button Indicator SOC Indicator Description Idle green blink 2 times Standby green blink 1 time Working steady green SOC 5 5 SOC 25 25 SOC 50 50 SOC 75 75 SOC 95 SOC 95 SOC Indicator B...

Page 23: ...les service Others Contact the after sales service Button Indicator SOC Indicator Fault Solutions Steady Red Battery Overvoltage Restart the battery If the problem persists contact the after sales ser...

Page 24: ...n off the air switch 2 Make sure that both the SOC indicator and the button indicator of the control unit are off Steady Red Relay Fault Restart the battery If the problem persists please contact the...

Page 25: ...en Contact After sales for help if the conductive wire is exposed because high voltage danger exists Do not touch or disassemble privately In case of other emergencies contact the After sales as soon...

Page 26: ...340 00627 02 GoodWe Technologies Co Ltd No 90 Zijin Rd New District Suzhou 215011 China www goodwe com service goodwe com GoodWe Website Local Contacts PV Master App...

Reviews: