05 System Installation
12
User Manual V1.0-2022-02-18
5.4 Electrical Connection
5.4.1 Connecting the PE Cable
5.4.2 Connecting the Power Cable
Crimping Length: 7.5±0.2mm
Crimping Hight: 7.5±0.2mm
Notice
•
Connect the PE cable first before installing the equipment. Disconnect the PE cable before
dismantling the equipment.
•
The PE cable should be prepared by customers.The cross-sectional area of the PE cable
conductor: 5mm
2
. The cable should meet standards for outdoor use.
• The drawing force of the cable after crimping should be at least 400N.
•
Connect the PE cable to the PCU or to the base in the same way.
Notice
•
Power off the Battery System before connecting the power cable to avoid high voltage
danger.
•
The DC input cable should be prepared by customers.Connect the red power connector to
the red wire harness. And the black power connector to the black wire harness. The cable
should meet standards for outdoor use.
•
The recommended tool is a manual hydraulic press plier.Crimping height: 7mm,
Mould:16mm
2
(AWG 6).
• Screw the nut and make sure there is no space.
• Use any one of the two power ports. The reserved one should be protected using a cover.