08 Maintenance
User Manual V1.0-2022-02-18
22
Item
Period
Check the wall mounting plate, fix it if it is not secured
Once every 6 months
Check whether the outer enclosure is broken. Repair the
painting or contact After-sales Service if there is any broken.
Once every 6 months
Check whether there is an exposed cable. Replace the exposed
cable or contact After-sales Service for help.
Once every 6 months
Check whether there is debris accumulation around the Battery
Module to avoid affecting heat dissipation.
Once every 6 months
Check for water and pest to avoid prolonged intrusion.
Once every 6 months
WARNING
•
Contact After-sales Service for help if you find any problems that may influence the Battery
Module or the inverter. Disassemble without permission is strictly forbidden.
•
Contact After-sales for help if the conductive wire is exposed because high voltage danger
exists. Do not touch or disassemble privately.
•
In case of other emergencies, contact the After-sales as soon as possible. Operate following
the instructions of the After-sales personnel. Or wait for the After-sales operators.
Communication
CAN
Weight (Kg)
115kg
158kg
201kg
244kg
Dimensions (W*D*H) (mm)
600*380*625
600*380*780
600*380*935
600*380*1090
Operating Temperature (℃)
Charge
:
0<T
≤
50 ; Discharge: -20<T
≤
50
Storage temperature (℃)
20~45 (
≤
One Month); 0~35 (
≤
One Year)
Humidity(%)
≤
95
Altitude (m)
≤
2000
Enclosure Type
IP55(Outdoor / Indoor)
Installation Location
Ground-Mounted
Standard and
Certification
Safety
IEC62619, CEC
EMC
CE, RCM
Transportation
UN38.3
*1: Test conditions, 100% DOD, 0.2C charge & discharge at +25±3 °C for battery system at beginning life.
System Usable Energy may vary with different Inverter.
*2: Nominal Dis-/Charge Current and power derating will occur related to Temperature and SOC.