background image

DESCRIPTION OF THE WALL MOUNT CONNECTION BLOCK

7

TEKNA PLUS SE MONITOR

Description of the RCTK-PLUS wall mount connection block:

a

a

b

b

f

e

d

c

8

4

2

9

8

9

8

0

1

1

8

5

1

90

50mm.

50mm.

Colocar la parte superior de la regleta a 1,60m. del suelo.

Place the top part of the monitor connector at 1,60m.
from the floor.

Distancia mínima entre los laterales de la regleta y

cualquier objeto debe ser de 5cm.

Presionar para abrir.

Press to open.

CODE

11742080

REF

RCTK-PLUS

LOTE

IMP903012

Max.

5mm

CABLE

Max. pelado del cable.
Max. peeled cable.

Max. câble dénudé.
Max. aanstrip lengte.

V

in

V

out

Malla

Shield

MP

Malla

Shield

CETK590

A
D

INT

SA

CTO
OA1

VP

OA1

( )

*

( )

*

( )

*

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

V

in

V

out

Malla

Shield

HZ-
INT

SA

AP+

2C

VP

MP

Malla

Shield

A1

PLUS

A
D

V

in

V

out

Malla

Shield

HZ-

SA
2C

A1
VP

MP
MP

Malla

Shield

VP

a.

(x6).

Holes for fixing to wall

b.

(x2).

Monitor fixing clips

c.

Vertical wiring entry.

d.

Fixing clip.

e.

Central wiring entry.

f.

Connection terminals:

positive, negative

.

video signal input through coaxial cable.

.

coaxial cable mesh
video signal output through coaxial cable.

.

audio communication

.

digital communication

.

door bell push button input
intercom.

.

auxiliary call repeater output

.

auxiliary door opening push button input

.

2nd camera activation output
auxiliary device activation output.
balanced video signal (through twisted pair).

+,

:

Vin :
M

:

esh

Vout :
A :
D :
HZ- :
INT :
SA :

:

AP+
2C :
A1 :
Vp, Mp :

The +, and mesh terminals are duplicated to facilitate the cascade connection of other monitors or telephones. If the

-

monitor is not positioned on the wall mount connection block, the cascade connected monitors or telephones will not
receive power.

Summary of Contents for Tekna Plus SE

Page 1: ...Code 50123594 T EN TEKNA PLUS SE REV 0 1 2 6 TEKNA PLUS SE MONITOR USER MANUAL TECHNOLOGY...

Page 2: ...een the door panel power supply distributors and monitors Always follow the instructions contained in this manual Introduc n 2 tio Contents 2 Safety precautions 2 Characteristics 3 System operation 3...

Page 3: ...ior door panel of the building being called and other possible general entrance door panels automatically disconnect If another visitor attempts to call from either a busy interior door panel a number...

Page 4: ...installation fill in the label with the relevant information MASTER main monitor SLAVE secondary monitor INTER secondary monitor with intercom function A1 monitor connected to an auxiliary device COD...

Page 5: ...l mode is only available with theTekna Plus SE monitor This only functions if no call or communication is in progress Regardless of the position of the handset the auxiliary device is activated With t...

Page 6: ...monitor To insert the EL562 module remove the jumper that is in the connector NOTE In this type of installation set the SW1 3 DIP switches on the sound module of the door panel to ON see instruction m...

Page 7: ...T SA AP 2C VP MP Malla Shield A1 PLUS A D Vin Vout Malla Shield HZ SA 2C A1 VP MP MP Malla Shield VP a x6 Holes for fixing to wall b x2 Monitor fixing clips c Vertical wiring entry d Fixing clip e Cen...

Page 8: ...5cm Place the monitor at right angles to the wall mount connection block and align the holes on its base with the fixing clips of the connection block as shown in the drawing Close the monitor like a...

Page 9: ...tant To perform this programming the monitor s SW2 DIP switches should be set to OFF Switch off the monitor to be programmed Once switched off press the door release push button While keeping the door...

Page 10: ...amming switch to OFF If this is not done the door panel will emit tones to indicate that the system is still in programming mode 1 2 3 4 5 6 7 8 9 10 Factory setting DIP3 to DIP10 To set the monitor a...

Page 11: ...n is reached the following press returns the user to the first selection and 1 blink of the programming LED carousel mode Changing the ringtone melody Then select the melody for the ringtone selected...

Page 12: ...evice activation A1 call to s second camera lave porter s exchange activation 2C and intercom When the final selection is reached the following press returns the user to the first selection and 1 blin...

Page 13: ...s indicated with blinks 1 to 4 blinks of the programming LED and in the following order 60 90 120 and 150 seconds When the final selection is reached the following press returns the user to the first...

Page 14: ...on for 3 seconds and the programming LED will turn off When exiting advanced programming mode the monitor will turn off Press button for 3 seconds to turn the monitor back on After any resetting of th...

Page 15: ...220 V ac 1 8A max SAR 12 24 F N IN IN NC NA C The neutral of the lighting power supply is arranged serially through the contacts of the SAR 12 24 relay and the maximum consumption of the element to be...

Page 16: ...es to call slave 2 4 times to call slave 3 and 5 times to call slave 4 This selective intercom call mode is only available with the Tekna Plus SE monitor This only functions if no call or communicatio...

Page 17: ...tures as standard the ability to receive calls from the apartment front door This feature precludes the need to use the bell by positioning a switch between terminals HZ and of the monitor The rington...

Page 18: ...in Vout Vout CN4 CN4 A _ D Mesh Vin Vout CN4 A _ D Mesh Vin Vout CN4 E E D1 D1 D2 D2 D4L PLUS D4L PLUS JP1 JP1 S S SW1 SW2 M Master M D Mesh Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5...

Page 19: ..._ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562 JP1 Vp Mp A D _ EL562 JP1 JP1 A A D D CT Vpi Vd1 Mpi Md1 _ _ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562 JP1 Vp Mp A D _...

Page 20: ...olmar se reserva el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior no...

Reviews: