INSTALLATION OF THE MONITOR
Fixing the monitor's wall mount connection block to the wall:
8
Avoid dusty or smoky environments or locations near sources of heat.
To fix the monitor directly to the wall, drill four Ø6mm holes and use the
plugs and screws supplied.
The top of the wall mount connection block must be positioned at a
height of 1.60m. The minimum distance between the sides of the
wall mount connection block and the closest object must be 5cm.
Place the monitor at right angles to the wall mount connection block
and align the holes on its base with the fixing clips of the
connection block, as shown in the drawing.
Close the monitor like a book, applying pressure to the right-hand
side until the click of the connection block's fixing clips can be
heard.
To remove the monitor from the connection block after installation,
use a flat screwdriver to release the fixing clips. Once the monitor
has been released, open it like a book and remove it from the
connection block, making sure that it does not fall.
Fixing the monitor's wall mount connection block to the wall:
TEKNA PLUS SE MONITOR