Continued from the previous page.
10
TEKNA PLUS SE MONITOR
PROGRAMMING THE MONITORS
To programme the monitor as
, press button
and the status LED will
Slave without video
blink green once. If button
is pressed again, the monitor will return to being programmed
as
, and the status LED will blink green twice. The door panel video will be
Slave with video
displayed during a call depending on whether the monitor has been programmed as: Slave
with video or Slave without video.
SV
Each apartment must only have one master unit; if there are parallel units, either monitors or telephones, they must be
configured as slaves.
Make a call to check that the monitor has been successfully programmed. Programme the
other telephones in the same way
.
Once the programming has finished, set the programming switch to OFF. If this is not done, the
door panel will emit tones to indicate that the system is still in programming mode.
1
2
3
4
5
6
7
8
9
10
*
Factory setting
DIP3 to DIP10: To set the monitor address (addresses 1 to 255). The switches set
to OFF have a zero value.
The values of the switches set to ON are shown in the table below.
The monitor code is the sum of the values of the switches set to ON.
DIP1 and DIP2: To set the monitor as master / slave. DIP1 and DIP2 to OFF, master, DIP1
to ON and DIP2 to OFF, slave 1, DIP1 to OFF and DIP2 to ON, slave 2, DIP1 and DIP2 to
ON slave 3.
Example:
64+0+16+0+4+2+1=87
0+
Switch number
:
ON:
Value when
4
64
5
32
6
16
7
8
8
4
9
2
10
1
3
128
Quick programming of the Tekna Plus SE monitors:
The SW2 DIP switch is located on the left-hand side of the back of the monitor.
It enables the monitor to be configured as master / slave and an address to be
assigned.
Important:
This type of programming cannot be performed on a general
entrance door panel.