19
Inspect and tighten all parts of the elliptical regularly.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild dish soap.
IMPORTANT: Keep liquids
away from the console and keep the console out
of direct sunlight. During storage, remove the bat-
teries from the console.
CONSOLE TROUBLESHOOTING
If the console displays become dim, replace all the
batteries at the same time; most console problems are
the result of low batteries. See assembly step 9 on
page 9 for replacement instructions.
If the handgrip pulse sensor does not function prop-
erly, see step 5 on page 17.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted.
To adjust the reed switch, you must remove the stabi-
lizer covers, the pedal arms, the right pedal disc, and
the right shield.
First, see step 2 on page 6 and step 4 on page 7 and
remove the front and rear stabilizer covers.
Next, see steps 17 and 16 on page 13 and remove
the Left and Right Pedal Arms (11, 12).
Then, remove the Screws (51) from the right Pedal
Disc (15), and remove the right Pedal Disc.
Remove all Screws (52, 64) from the Right Shield (4),
remove the two Bolts (41), and remove the Right
Shield.
Locate the Reed Switch (53). Loosen, but do not
remove, the M4 x 16mm Self-tapping Screw (52).
Next, rotate the Disc Crossbars (16) until a Magnet
(58) is aligned with the Reed Switch (53). Slide the
Reed Switch slightly toward or away from the Magnet.
Then, retighten the Self-tapping Screw (52).
Rotate the Disc Crossbars (16) for a moment. Repeat
these actions until the console displays correct feed-
back.
When the reed switch is correctly adjusted, reattach
the right shield, the right pedal disc, the pedal arms,
and the stabilizer covers.
MAINTENANCE AND TROUBLESHOOTING
51
41
41
64
64
64
64
52
52
52
51
12
4
15
3
58
52
53
16