1. Room Ventilation
This cooktop must be installed in a room that has permanent ventilation to effect
the correct operation of the appliances and also to provide adequate ventilation.
This airflow must exceed 20m³ via permanent vented openings in the walls of the
room and these must have a section of 100cm² minimum. They must be
constructed in a manner so as to avoid any possible blockages. The airflow can
also be drawn indirectly from an adjacent room provided it complies with any local
regulations to vent any fumes outdoors.
Not for use in Marine craft, caravans or Mobile homes unless
fitted with safety device.
2. Before installing the appliance check that the location provides the required clearances
from combustible materials and if necessary provide protection to adjacent surfaces as
required by the regulations. Make provision for the gas supply to be connected in the
position shown in Diagram A.
3. Cut the opening in the bench top to the dimensions shown in diagram B.
4. Remove the hotplate from the carton.
5. Install the hotplate in the cut-out (see diagram B on page 2).
Note:
If clearance between side and rear walls and periphery of the burner is less than 250mm,
the walls must be protected with a non-combustible material. The protection must extend
a minimum distance of 450mm above the burner. Horizontal surfaces less than 750mm
vertically above the hotplate must also be protected.
6. Ensure that gas and electrical outlet are accessible with the appliance installed. The
gas connection to the regulator is 1/2” BSP. Please ensure gas supply line to
the
appliance is of adequate length to allow sufficient withdrawal of appliance for service or
disconnection. The connection must be annealed copper pipe or flexible hose (if
permissible by local authority).
Note:
The cook top must be installed with provision to allow the gas to be turned off and
disconnected for servicing and removal of the appliance as required from gas supply.
7.
Use a spanner at the flat area provided to hold the regulator firmly, when making the
join. Refer diagram below.