WARNING
:
-
DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IT IS IN OPERATION.
-
SOME PROPELLANT GASES CAN BREAK DOWN WHEN HEATED AND PRODUCE CORROSIVE
VAPOURS, WHICH WILL ATTACK SOME MATERIALS.
-
ARTICLES, WHICH ARE MADE OF FLAMMABLE MATER SHOULD NOT BE STORED IN DRAWERS
OR
CUPBOARDS IMMEDIATELY BELOW THIS APPLIANCE.
-
THE SILICONE RUBBER GASKET SHOULD NOT BE REMOVED UNDER ANY CIRCUMSTANCES. IN
THE EVENT THAT ANY PROTECTIVE RUBBER GASKET IS DROPPED OFF OR DAMAGED, THE
CONSUMER SHOULD CEASE FORTHWITH THE USE OF THE UNIT UNTIL IT IS DULY RECTIFIED.
-
DO NOT STORE ARTICLES WITHIN 50MM OF THE BOTTOM OF THE HOTPLATE CASING.
-
DO NOT TOUCH SPARK IGNITOR WHILE LIGHTING THE BURNER.
-
WHEN THE APPLIANCE IS INSTALLED IN A MARINE CRAFT OR IN A CARAVAN, IT SHALL NOT BE
USED AS A SPACE HEATER.
-
DO NOT MODIFY THIS APPLIANCE.
SERVICING INSTRUCTIONS
WARNING!
DANGER 220 VOLTS 50Hz.
DISCONNET POWER BEFORE SERVICING UNIT
DO NOT MODIFY THIS APPLIANCE
MINOR ADJUSTMENT
Access to By Pass Screw
-
Light the burner and turn to
minimum setting (marked small
flame).
-
The flame should be stable
on minimum setting and should not
extinguish when passing from
maximum setting to low setting. - If
adjustment is necessary, remove
the control knob by pulling upward.
The bypass screw is accessible via
the control knob spindle. Turn the
bypass screw anti-clockwise to
increase the turn-down rate
Access to manifold, gas taps and burner
assembly
-
Remove glass hob and control knobs.
-
To remove gas cocks. Unscrew the locking
nut (between cock and burner). Remove screws, the
cock can now be removed from the manifold. If
access to the barrel is required, remove two screws,
which retain spindle to body. If lubricating the
mechanism use Regosine Moly LM or other
approved grease. To replace electrode
-
Remove screw from the clamp holding the
electrode and thermocouple and note the
adjustment setting height of each. Replace electrode
and then fit clamp and screw.
FAULT ISOLATION CHART
FAULT
CAUSES
REMEDY