8.
Once they are tightened securely, turn
the gas on and check for leaks using a soap
solution and brush around all joints and
connections.
Pressure test point for LP and ULP gas only.
Use the regulator provided for town and natural gas.
Pressure test poin
9.
t:
- This is provided in the gas regulator.
- Remove the screw; connect the hose from the pressure gauge.
- Turn on the gas to the large burner and manually light the burner.
- The pressure is shown on the data plate.
- To increase the pressure, loosen locking nut and turn clockwise.
- Disconnect gauge and replace test point screw.
10. Test the appliance:
- Depress each control knob and turn to full flame setting.
- The burner will ignite. Adjust control knob to desired setting. Normally, no
adjustment should be necessary.
- If any problem occurs, refer to the servicing instruction of the faultfinding chart.
11. Please make sure that gas supply connection is easily accessible for servicing or
other purpose.
12. Stick the second data label (which is provided in the box) at a place, which is
noticeable, e.g.: inside the cabinet door or the sidewall.
13. Instruct the user to keep the user instruction manual.
If any of the above procedures do not produce satisfactory
results, the agent’s
service department should be consulted for more specialize assistance.
14. Please note that the cooktop is fitted with the flame failure device that cuts off the gas
supply when burner flame extinguishes suddenly or abnormally in order to avoid gas
leakage.
WARNING!
NOT FOR USE IN MARINE CRAFT, CARAVANS OR MOBILE HOMES UNLESS
FITTED WITH SAFETY DEVICE.