16
Note that Aux1 and Aux2 configuration are identical. Follow the steps below to program either output.
Aux1 Config.
+ to view/change
Aux1 Function
Manual On/Off
Aux1 Interlock
Disabled
Aux1 Freeze
Disabled
+
+
+
+
>
>
>
>
>
>
>
>
Push to access Aux1 options
Rotates between
options
Manual On/Off, Countdown Timer, Timeclock, Solar, and
Low speed of a 2-speed pump
Toggle between Enabled and Disabled (default) Aux1 Interlock
Toggle between Enabled and Disabled (default) Aux1 Freeze
Move to previous/next configuration menu item
Move to next menu item
Move to next menu item
Move to next menu item
for all functions except solar
!
WARNING: Do not use the Aqua Logic to control an automatic pool cover. Swim-
mers may become entrapped underneath the cover.
Aux1 Function (Aux2 Function)
Manual On/Off (default)
—the aux relay will alternate between turning on and off when the
aux button is pressed. There is no automatic control logic.
Countdown Timer
– the aux relay will turn on when the aux button is pressed and then will
turn off automatically after a programmed time (see Timers Menu in the Operations Manual).
The aux button can also be used to turn the output off. This function is typically used to
control spa jets where they can be turned on with the press of a button and then they will
turn off automatically at a later time.
Timeclock
– the aux relay will turn-on and turn-off at the times set for the aux1 (aux2)
timeclock in the Timers Menu (see Operations Manual).
Solar
– the aux relay operates a solar booster pump which will turn on when the filter pump
in running and solar heat is available and the water is less than the desired temperature
setting. It is important to note that “Solar Control” must be enabled in the “Solar Config.”
menu for proper operation to occur.
Low Speed of a 2-speed Filter Pump
– the Aqua Logic will operate the aux relay whenever
the low speed operation of the filter pump is required. It is very important that the “2-speed”
filter pump option be selected under the “Filter Config.” Menu for proper operation.
Aux1 Interlock (Aux2 Interlock)
If “Enabled”, this feature will override the function (manual on/off, countdown timer, timeclock,
selected above and turn the aux1 or aux2 relay off. This forced off condition occurs when:
filter pump is off, first 3 minutes of filter pump operation (allows the pump to prime and get
water flowing), when the pool/spa suction return valves are in any position other than “pool
only”, for 3 minutes after solar turns on (allows air in the solar panels to be purged). Interlock
is not available for solar or lowspeed filter pump functions.
Aux1 Freeze Protection (Aux2 Freeze Protection)
This function protects the pool, plumbing, and equipment against freeze damage. If Freeze
Protection is enabled and the AIR temperature sensor falls below 38°F, the Aqua Logic will
turn on the aux relay to circulate the water. IMPORTANT: this only enables operation of the
AUX output during freeze--see the “Filter Pump Config.” menu to enable freeze protection
for the main circulation system.