Turning on and off the detector

To turn on the detector, hold the ON/OFF button for 2 seconds - a world map graphic will 

appear on the screen. From this stage to operation stage around 10 seconds are required 

for the detector software to load.
To turn off the detector, press and hold the ON/OFF button. A screen with HOLD TO TURN 

OFF will appear. Hold until a POWER OFF screen appears and then release the button.

WARNING!

THIS PART IS VERY IMPORTANT,

READ IT CAREFULLY!

When you turn on the detector, the coil must be at 

least 50 cm (20”) high from the ground, and far from 

any metal objects. After the software loads, the detec-

tor performs a RESET of the electronics to pair the detector with the coil, according to the 

surrounding temperature and electromagnetic fields (if any).

You can manually do a reset at any time by pressing the ENTER button. 
A reset is REQUIRED every time after you change the working frequency or the 

PowerBox settings.

If the surrounding temperature is changing quickly, the detector may become nervous. In 

this case you should perform a reset prior of making any other changes, the reset resolves 

the problem in 99% of the occasions.

RESET

Selecting the working frequency

To select the detector working frequency, press the top-left button. A FREQUENCY label 

will appear on the screen and two options boxes at the bottom are present. You can navi-

gate between the options by pressing the + and - buttons. The selected option is marked 

with a diagonal grid. To select the desired frequency, select a box and confirm your choice 

by pressing ENTER.

After you’ve selected the frequency and confirmed with the ENTER button, a screen with 

nine options will appear (-4, -3, -2, -1, 0, 1, 2, 3, 4). This is the so-called frequency shift. By 

selecting one of these options, the working frequency changes slightly to avoid electro-

magnetic interference with similar devices or industrial electromagnetic fields. Select the 

desired value (the selected option is above the ENTER button), and confirm your choice 

with ENTER.

FREQUENCY

8KHz 18KHz

18 kHz

-1

0

-2

Summary of Contents for 5+

Page 1: ...Golden Mask 5 User Guide 18 kHz BITONAL GB 30 GAIN 1 THRESHOLD 25 P BOX LOW 69 IRON FOIL NICKEL COPPER SILVER...

Page 2: ...dual frequency coils Wireless headphones WS105 included in the package 5 years warranty of the electronics board To offer the 5 years warranty the Golden Mask metal detectors are made with only top le...

Page 3: ...ly from the handle part but we do not recoomend it because a plactic shim inside the locking screw could be lost or damaged Please be sure to have a minimum of 15 cm 6 inch of the third section inside...

Page 4: ...he ENTER button A reset is REQUIRED every time after you change the working frequency or the PowerBox settings If the surrounding temperature is changing quickly the detector may become nervous In thi...

Page 5: ...bove this border are shown with positive numbers The Iron Audio setting is shown with bi color bar just bellow the Spectrum VDI scale The black part of the Iron Audio bar shows targets that will sound...

Page 6: ...es better the deep iron signals 2 Two tone 2 In two tone or bitonal mode you hear both signals from ferrous and non ferrous targets Ferrous targets are indicated with a low sound while the sound respo...

Page 7: ...select the desired value with the and buttons and confirm with ENTER Ground balance GB The ground balance is a setting that compensates for different ground conditions There are soils with no to very...

Page 8: ...nd Balance To automatically adjust the ground balance press the ground balance GB button on the bottom left corner of the control panel then select the Auto option from the ground bal ance menu and co...

Page 9: ...ptions are 0 1 and 2 The higher the number the greater the overall signal amplification But be aware on mineralization higher number of the Gain does not always mean deeper penetration of the signal O...

Page 10: ...hen try the above two options The PowerBox setting is related to the working frequency In other words you could set different values for the two working frequencies The detector will remember the sett...

Page 11: ...activated a small icon appears below the battery icon on the main screen to show you the backlight is on when Controlling the LCD screen contrast You can change the LCD screen contrast To do this sho...

Page 12: ...e Automatically adjust from 6V 15V Max voltage with no load 20V Rated Current 500mA 450mA 600mA Trickle Current 35 50MmA Pulsel ratio 1 20 10mA Short Circuit Current 10 20mA Battery repairingl Current...

Page 13: ...ference EMI fields that will disturb the detector and you may think something s wrong On sites with not too many targets try to use the All metal mode this will give you 2 3 cm more depth If you canno...

Page 14: ...Golden Mask 5 User Guide GMD www goldenmaskdetectors com Golden Mask Official Distributor 26...

Reviews: