background image

Golden Mask 5+ User Guide

GMD - 

www.goldenmaskdetectors.com - Golden Mask Official Distributor

20

Golden Mask 5+ User Guide

GMD - 

www.goldenmaskdetectors.com - Golden Mask Official Distributor

21

Setting the sound tone

You can tune-up the sound frequencies for different targets by selecting the sound but-

ton (with the speaker icon), then select the TONE option and confirm with ENTER.

Then select the tone you want to change (for non-ferrous, ferrous or all targets) and select 

the desired frequency by pressing the - and + buttons. As usual, confirm your choice by 

pressing the ENTER button. The tone for All Metal mode applies to Mono-tone mode also.

A new screen with tone values will appear. Select the desired tone by pressing the - and + 

buttons. On every change, you will hear the signal from your selection, Once you choose 

the sound you like, confirm your choice by pressing the ENTER button.

Turning-on the backlight

To turn-on the LCD screen backlight (for search when it’s dark), just short-press the POWER 

LEVEL button and wait until the backlight icon appears. 

To turn the backlight off, short-press the POWER LEVEL button once. As simple as that. 
When the backlight is activated, a small icon appears below the battery icon on the main 

screen to show you the backlight is on when 

Controlling the LCD screen contrast

You can change the LCD screen contrast. To do this, short-press the ON/OFF button, then 

press the - and + buttons within 3 seconds after you’ve pressed the ON/OFF button. If you 

don’t press any button within 3 seconds, the backlight will be activated or deactivated.

Using the wireless headphones (except Light version)

Your Golden Mask 5+ is delivered with wireless headphones WS105. The wireless transmit-

ter is integrated in the battery compartment of the detector.
At the backside of the battery compartment you will find a small switch that routes the 

sound signal to the speaker or to the wireless transmitter. To use the wireless headphones, 

you just switch to WS position and the sound goes to the wireless transmitter. Now you 

have to switch-on the headphones by pressing and holding for 2 seconds the on/off but-

ton. When the headphones are ready to work, a red light will start to blink.
When used with the GM5, the WS105 headphones are operated by the three buttons on 

the right earphone: on/off, and volume-. The three other buttons on the left 

earphone are not used.

SELECT TONE

non-FE

All

ferrous

18 kHz
BITONAL
GB 30

GAIN 1
THRESHOLD 25
P.BOX LOW

+

69

IRON

FOIL NICKEL COPPER SILVER

SELECT

volume

tone

Summary of Contents for 5+

Page 1: ...Golden Mask 5 User Guide 18 kHz BITONAL GB 30 GAIN 1 THRESHOLD 25 P BOX LOW 69 IRON FOIL NICKEL COPPER SILVER...

Page 2: ...dual frequency coils Wireless headphones WS105 included in the package 5 years warranty of the electronics board To offer the 5 years warranty the Golden Mask metal detectors are made with only top le...

Page 3: ...ly from the handle part but we do not recoomend it because a plactic shim inside the locking screw could be lost or damaged Please be sure to have a minimum of 15 cm 6 inch of the third section inside...

Page 4: ...he ENTER button A reset is REQUIRED every time after you change the working frequency or the PowerBox settings If the surrounding temperature is changing quickly the detector may become nervous In thi...

Page 5: ...bove this border are shown with positive numbers The Iron Audio setting is shown with bi color bar just bellow the Spectrum VDI scale The black part of the Iron Audio bar shows targets that will sound...

Page 6: ...es better the deep iron signals 2 Two tone 2 In two tone or bitonal mode you hear both signals from ferrous and non ferrous targets Ferrous targets are indicated with a low sound while the sound respo...

Page 7: ...select the desired value with the and buttons and confirm with ENTER Ground balance GB The ground balance is a setting that compensates for different ground conditions There are soils with no to very...

Page 8: ...nd Balance To automatically adjust the ground balance press the ground balance GB button on the bottom left corner of the control panel then select the Auto option from the ground bal ance menu and co...

Page 9: ...ptions are 0 1 and 2 The higher the number the greater the overall signal amplification But be aware on mineralization higher number of the Gain does not always mean deeper penetration of the signal O...

Page 10: ...hen try the above two options The PowerBox setting is related to the working frequency In other words you could set different values for the two working frequencies The detector will remember the sett...

Page 11: ...activated a small icon appears below the battery icon on the main screen to show you the backlight is on when Controlling the LCD screen contrast You can change the LCD screen contrast To do this sho...

Page 12: ...e Automatically adjust from 6V 15V Max voltage with no load 20V Rated Current 500mA 450mA 600mA Trickle Current 35 50MmA Pulsel ratio 1 20 10mA Short Circuit Current 10 20mA Battery repairingl Current...

Page 13: ...ference EMI fields that will disturb the detector and you may think something s wrong On sites with not too many targets try to use the All metal mode this will give you 2 3 cm more depth If you canno...

Page 14: ...Golden Mask 5 User Guide GMD www goldenmaskdetectors com Golden Mask Official Distributor 26...

Reviews: