Area of Application
•
Commercial and industrial applications
•
Household
Place of operation
•
operate indoors
Do not install in areas where the temperature exceeds 50°C or falls below –20°C.
For outdoor applications, the product must be located or protected so that no
dripping water can enter. We recommend installation in under a hood and in a control
cabinet, respectively, or in a housing.
Installation location
•
for being installed in two cylinder system or multiple cylinder system
Installation position
•
horizontal
Right
Wrong
The automatic changeover valve must be installed so that the hose connections are at the
highest position; at least above the cylinder valve.
To prevent re-liquefied gas getting into the regulator, this pressure regulator may not be
installed lower than the tank or cylinder valve. Pipes and hoses that are connected to the
inlet connector of the pressure regulator must have a constant downward incline to the tank
or cylinder.