Ground check deactivated
Ground check deactivated
4 LEDs light up red (3, 6, 9 and 12 o‘clock).
The go-e Charger has the safety function
„ground check“, which prevents the char-
ging process in TT/TN power grids (common
in most European countries) in case of in-
sufficient grounding of the power connec
-
tion. This function is enabled by default and
can be disabled via the go-e Charger app.
However, the „Ground check“ should only be
disabled if you are sure that the electricity grid
has no grounding (IT grid, e.g. in many regions
of Norway), so that charging can also be carried
out here. If you are not sure, you must leave the
setting in the app at „Enabled“!
Waiting
Waiting
The LEDs flash blue in the number of preset
charging power.
The go-e Charger waits with the charging pro-
cess due to a preset scheduler or for the receipt
of cheap electricity.
Activation required
The LEDs light up blue and two white LEDs move
from the top and bottom to the centre.
The „Access control“/“Charging mode“ is not set
to „Open“. Use a learned RFID chip or the app to
activate the charging process.
RFID chip detected
5 LEDs light up green.
The go-e Charger has recognised an RFID chip
authorised for charging and releases the char-
ge.
10. LED status display/troubleshooting