go-e Gemini flex Installation And Operating Manual Download Page 20

20

20

6.

Stop charging

The charging process is completed when the 

LEDs light up green.

If you want to stop charging prematurely, use 

the „cable release“ function of your vehicle or 

the large round button of the go-e Charger app 

(tab „Charging“).

The cable remains locked in the type 2 socket in 

the standard setting after the charging process 

has ended (adjustable via the app) until it is re-

moved from the vehicle (theft protection).

If the power supply is interrupted, the char-

ging cable remains locked in the charging box 

for reasons of theft protection. To unlock it, it 

is necessary to re-energise the charging station. 

The cable can also be unlocked automatically 

after a power failure, provided the function has 

been activated in advance via the „Cable unlock“ 

setting in the app. However, it is then no longer 

theft-protected in the event of a power failure.

The go-e Charger displays the charging status 

via different colours and positions of the LEDs. 

In addition, it executes a whole series of safe

-

ty queries to check the used power source for 

possible errors. For this reason, the go-e Char-

ger may display an error and refuse to charge, 

especially with unknown power sources.

The device visualises the cause of the error by 

certain colours and positions of the LEDs. You 

can also find the error message within the „Sta

-

tus“ information of the app. (The following co-

lour codes correspond to the factory setting).

9. Commissioning/charging

10. LED status display/troubleshooting

oting

Summary of Contents for Gemini flex

Page 1: ...go e Charger Gemini flex 11 22 kW Installation and operating guide V 1 0...

Page 2: ...2 2 Content...

Page 3: ...uct overview page 10 Scope of delivery page 11 Technical data page 12 Installation page 15 Commissioning charging page 18 LED status display troubleshooting page 20 Reset card RFID chip page 24 App pa...

Page 4: ...arging station for EVs Smart and intelligent solu tions that make charging electric ve hicles even more convenient are al ready integrated in the go e Charger Gemini flex The charging unit was develop...

Page 5: ...to charge in an environ mentally conscious way you should if possible postpone your charging with the go e Charger Scheduler function to the midday or the early morning hours as there is a surplus of...

Page 6: ...such as a registration or approval requi rement for charging stations or the limi tation of single phase charging Registration information Please contact your electricity grid ope rator to find out wh...

Page 7: ...s running water or heat emitting equipment Electrical protective measures installation operation High voltage danger to life Never use the go e Charger if the housing is dama ged or open In case of un...

Page 8: ...eration with 16 A Na tional regulations may prescribe lower The go e Charger has to be used hanging vertically or must be mounted vertically in the wall bracket on a flat wall Make sure that the power...

Page 9: ...the obligation to register or obtain approval for ev charging stations or the limitation of single phase charging Con tact your grid operator electricity provi der to find out whether the go e Charger...

Page 10: ...erformance plastic RFID reader Release of charging processes with RFID chips or cards can be activated via app Button Change of charging strength 5 levels adjustable via app LED ring Display of chargi...

Page 11: ...s 11 or 22 kW charging box with 16 A or 32 A CEE red plug Wall bracket Type 2 cable up to 22 kW 2 5 m 5 m 7 5 m Type 2 cable holder Type 2 to Type 1 cable 7 4 kW 5 m RFID chips pack of 10 go e Charger...

Page 12: ...bient conditions Gemini flex 11 kW Gemini flex 22 kW Installation site Indoors and outdoors without direct sunlight Operating temperature 25 C to 40 C Storage temperature 40 C to 85 C Average temperat...

Page 13: ...control Modbus TCP e g for grid serving power control by the electricity grid operator Charging capacity Gemini flex 11 kW Gemini flex 22 kW Remark Single phase charging car 1 4 kW to 3 7 kW 1 4 kW to...

Page 14: ...t of RFID chips cards up to 10 users per charger Access control RFID App OCPP 1 6 Electricity meter total kWh and total amount per RFID chip kWh limit mode ECO mode Planned charge mode Push notificati...

Page 15: ...ctly below the CEE socket so that little pressure is exerted on the supply line Place the wall bracket in the desired mounting position Use a spirit level to align it straight Mark the four drill hole...

Page 16: ...n a padlock not included in the scope of delivery can be attached 2 Drill holes at the four marked positions 4x 3 Attach the wall bracket with four screws and do wels each Drive the dowels into the wa...

Page 17: ...g side unless local regulations deviate from this In addition a miniature circuit breaker must be installed upstream Miniature circuit breakers with characteristic B or C for 16 or 32 amperes are perm...

Page 18: ...ton 1 LED 1 A Gemini flex 11 kW 6 A 16 A Gemini flex 22 kW 6 A 32 A 1 Start of the charger The go e Charger performs a self test during initial start up or after a restart during which the LEDs light...

Page 19: ...charging current 9 Commissioning charging Charging After the car has enabled charging the LEDs rot ate clockwise around the type 2 socket during the charging process The number of tails corresponds to...

Page 20: ...unlocked automatically after a power failure provided the function has been activated in advance via the Cable unlock setting in the app However it is then no longer theft protected in the event of a...

Page 21: ...ns of Norway so that charging can also be carried out here If you are not sure you must leave the setting in the app at Enabled Waiting Waiting The LEDs flash blue in the number of preset charging pow...

Page 22: ...and glow green yellow statically at the bottom Check whether the supply line to the go e Char ger is properly grounded Unknown RFID chip 5 LEDs light up red An unknown RFID chip was used Use a learned...

Page 23: ...perature in the go e Charger is increa sed Therefore the charging current is automa tically reduced Error unlocking or locking The LEDs briefly light up red at the top and yel low at the bottom The ch...

Page 24: ...work Firmware update failed The LEDs light up alternately red and pink The firmware update could not be completed successfully Please try again 11 Reset card RFID chip go e Charger reset card On the b...

Page 25: ...be held in front of the RFID reader below the logo of the charger before each charging process Alternatively authentication can be done by tapping the round button of the tab Charging of the go e Char...

Page 26: ...es require deactivating mobile data and terminating active WiFi connections 2 Either scan the QR code of the reset card an external app may be required for this or manually search for the charger s ne...

Page 27: ...iFi SSID or se lect your WiFi if displayed You also need to enter the password of this WiFi network As soon as the connection has been esta blished a Next button appears which you have to tap Follow t...

Page 28: ...stop the charging process by tapping this circle In this case you are charging in standard charging mode which does not take into account e g the flexible energy tariffs Use the 3 round icons below t...

Page 29: ...have a positive effect on the stability of the power grid With high ampera ges you charge the battery faster kWh Limit The kWh Limit function is practical if you do not want to fully charge the batter...

Page 30: ...working day and take electricity that could otherwise not be used sen sibly In this way you ensure grid stability After activating the scheduler you can define when the go e Charger may charge or not...

Page 31: ...e shall be no claim to reimbursement of costs under the guarantee 4 In the event of incorrect storage use or installation mounting by the buyer installer and resul ting damage to the product or other...

Page 32: ...adio equip ment type go e Charger Gemini flex 11 kW and go e Charger Gemini flex 22 kW is in compliance with Directive 2014 53 EU The full text of the EU Declaration of Conformity is available at the...

Page 33: ...ques tions help for technical problems and troubleshooting on www go e com If you cannot find an answer to your question in this guide on our web site or in the app please feel free to contact us go...

Page 34: ......

Reviews: