20
Installer Programming
RF Sensor Programming
RF Sensor Programming Outline
The Control Panel can be programmed with up to 48 RF sensors
of different types. In addition to the 48 multi-purpose RF sensors,
eight RF remote control key fobs and four RF remote control
keypads can be programmed into the system.
Programming the RF sensors into the Control Panel involves
selecting the sensor number for a particular device, selecting the
RF sensor type, setting or learning the RF sensor’s serial number,
and selecting the other options for the sensor.
• RF sensors #1 - #48 report as system sensors #1 - #48
Refer to Figure 49 for an outline of the steps required to program
RF sensors into the Control Panel. The options that can be set for
each RF sensor are:
•
Sensor Number
— Sensor number 01-48
•
Sensor Type
— Exit/entry, perimeter, interior, etc.
•
Sensor Equipment Type
— Certain sensor
types will ask for equipment type
•
Sensor Equipment Code
— Sensor model
(door/window, PIR, smoke detector, etc.)
•
Sensor Other Equipment Code
— Enter special
equipment code (only shown for sensors set as “other”)
•
Sensor Serial #
— Serial number labeled on sensor;
manually enter or “learn” by sending signal
•
Sensor Equipment Age
— New install or existing sensor
•
Sensor Loop Number
— Built-in contacts or
external contacts on DW10 door/window sensor
•
Sensor Dialer Delay
— Delayed or instant
communicator reports for the sensor (delay
time is set by dialer abort window)
•
Sensor Voice Descriptor
— Name assigned to the sensor
•
Sensor Reports
— Communicator reports or
no communicator reports for the sensor
•
Sensor Supervised
— Control Panel checks for status
reports from the sensor, or does not check for status reports
•
Sensor Chime
— Select voice announcement
and chime options for the sensor