Page 2: ...nsions 18 Operation 20 Maintenance 22 Precautions 22 Cleaning 24 Troubleshooting 26 Final Considerations 27 Descripción del Producto 28 Garantía del Equipamiento 31 Datos Generales 31 Especificaciones Técnicas 38 Simbolos 41 Dimensiones 43 Funcionamiento 45 Mantenimiento 47 Precauciones 47 Limpieza 49 Imprevistos 51 Consideraciones Finales 52 ...
Page 3: ...handle both with round edged finishing and made of high impact ABS plastic and Round light and flexible hoses without grooves Gradual foot control for hand pieces operation Disinfections system using the Bio system allowing hose and internal cleaning hand pieces using disinfectant liquid this preventing the risk of crossed contamination With Water reservoirs for syringe and hand pieces spray chlor...
Page 4: ...s that may cause explosion After finish life cycle of the equipment this equipment is throw way so it should to be destroyed in appropriate area according to the legislation of the country To guarantee the safe functioning of your equipment use only the assemble configurations Dental Chair Dental and Water Units and Dental Light supplied by Gnatus authorized Dealers Technical Assistance Delivery u...
Page 5: ...technology it has already its second generation The safety and efficiency of LEDs now with high energy of emission its useful to all clinical procedures which need the potency of light for photo activation including the ambulatorial bleaching treatment The wave length of 470nm associated to high energy generated by Optilight LD makes possible the multifunction of this equipment Direct restoring pr...
Page 6: ...t this manual can t solve ask for an Authorized Gnatus Technician List of pieces and circuit scheme Gnatus Company declares that the supply of the circuit scheme list of pieces or any other information that propitiate technical attendance for the user can be request if there is an agreement between the user and Gnatus Company PRODUCT DESCRIPTION lamps lose a great deal in the process The Optilight...
Page 7: ...e water adjustment valve FO MME Scaler Bicarbonate jet 01 02 03 04 05 07 08 09 10 11 12 13 14 15 16 17 18 20 21 22 23 19 Syncrus GLXC FULL 01 Auxiliary trays 02 Control panel 03 X ray view 04 Triple syringe 05 High speed motor terminals FO 07 Centered handle 08 Low speed motor terminal TB TM 09 Scaler 10 Bicarbonate jet 11 Delivery unit main switch 12 Scaler potentiometer 13 Electric low speed mot...
Page 8: ...inge water adjustment valve FO Scaler Bicarbonate jet 01 02 03 04 05 07 08 09 10 11 12 15 16 17 18 20 21 22 23 19 Syncrus GLXC 01 Auxiliary trays 02 Control panel 03 X ray view 04 Triple syringe 05 High speed motor terminals TB TM FO 06 High speed motor terminals TB TM 07 Centered handle 08 Low speed motor terminal TB TM 09 Scaler 10 Bicarbonate jet 11 Delivery unit main switch 12 Scaler potentiom...
Page 9: ...2 Arm s brake valve 23 Syringe water adjustment valve FO Scaler Syncrus GLC SONIC 01 Auxiliary trays 02 Control panel 03 X ray view 04 Triple syringe 05 High speed motor terminal TB TM FO 06 High speed motor terminal TB TM 07 Centered handle 08 Low speed motor terminal TB TM 09 Scaler 11 Delivery unit main switch 12 Scaler potentiometer 15 Manometer 19 Instrument s support 20 Connection box 21 Foo...
Page 10: ...e valve 23 Syringe water adjustment valve FO Bicarbonate jet Syncrus GLC JET 01 Auxiliary trays 02 Control panel 03 X ray view 04 Triple syringe 05 High speed motor terminal TB TM FO 06 High speed motor terminal TB TM 07 Centered handle 08 Low speed motor terminal TB TM 10 Bicarbonate jet 11 Delivery unit main switch 15 Manometer 16 Bicarbonate reservoir 19 Instrument s support 20 Connection box 2...
Page 11: ...uctor 57 Light conductor Whitening Tip 01 Auxiliary trays 02 Control panel 03 X ray view 04 Triple syringe 05 High speed motor terminal TB TM FO 06 High speed motor terminal TB TM 07 Centered handle 08 Low speed motor terminal TB TM 11 Delivery unit main switch 15 Manometer 19 Instrument s support 20 Connection box 21 Foot control 23 Syringe water adjustment valve FO 24 Rotation of the pedestal 25...
Page 12: ... control 22 Arm s brake valve 23 Syringe water adjustment valve FO 01 02 03 04 05 07 08 11 15 17 18 20 21 22 23 19 Syncrus GLC 01 Auxiliary trays 02 Control panel 03 X ray view 04 Triple syringe 05 High speed motor terminal TB TM FO 06 High speed motor terminal TB TM 07 Centered handle 08 Low speed motor terminal TB TM 11 Delivery unit main switch 15 Manometer 19 Instrument s support 20 Connection...
Page 13: ...O 14971 Medical devices application of risk management medical devices ISO 9687 1993 Dental equipment graphical symbols ISO 7494 Norma dental units ISO 13485 2 Quality systems medical devices ISO 780 Packaging pictorial marking for handling goods ISO 11144 Norma dental equipment connections for suply and waste lines IPX 0 Application together with anesthetic products that could be inflammable in t...
Page 14: ... units With maximum piling up of 07 units for storage Cart delivery units With maximum piling up of 04 units for storage Content of accessible and non accessible demarcations Operation mode Continuous with intermittent load 90 sec operating with a pause of 90 seg Electric shock protection type Class one equipment Degree of protection against electric shock BF type Input 5 2V Optilight LD Power 5 2...
Page 15: ...ic low speed motor D Scaler Syncrus GLX F C FULL Delivery Unit Syncrus GLX F C Delivery Unit Syncrus GL F C SONIC Delivery Unit Syncrus GL F C JET Delivery Unit Syncrus GL F C OPTI Delivery Unit Syncrus GL F C Delivery Unit E Bicarbonate Jet F High speed terminal G Low speed motor terminal H Optilight LD ...
Page 16: ...s water flow Cup filling High speed terminal Low speed motor terminal Optilight LD available in GLF OPTI and GLC OPTI Delivery Units Triple syringe Bicarbonate Jet available in GLXF FULL GLXC FULL GLXF GLXC GLF JET and GLC JET Delivery Units Turned on Turned off Scaler indicator key available in the GLXF FULL GLXC FULL GLXF GLXC GLF SONIC and GLC SONIC Delivery Units Perio function operation avail...
Page 17: ...XF FULL and GLXC FULL Delivery Units Landing in many parts of the equipment indicates the condition of being landed B type equipment Packing flex delivery units to be stored with a maximum stack of 7 units Packing cart delivery units to be stored with a maximum stack of 4 units 04 07 Packing to be transported and or stored avoiding humidity rains and wet floor Packing to be transported and or stor...
Page 18: ...TECHNICAL SPECIFICATIONS Dimensions mm Syncrus GLXF FULL GLXF GLF SONIC GLF JET GLF OPTI and GLF Delivery Units Note Drawing above represents a GLXF Delivery Unit All other models have identical dimensions ...
Page 19: ... 19 Dimensions mm Syncrus GLXC FULL GLXC GLC SONIC GLC JET GLC OPTI and GLC delivery units TECHNICAL SPECIFICATIONS Note Drawing above represents a GLXC Delivery Unit All other models have identical dimensions ...
Page 20: ...he Bowl water key 34 for 3 seconds a long beep will be heard and the LED will keep blinking When the desired time is reached press the Bowl water key again The cup filling time is then set The Cup filling and Bowl water time functions have a limited preset flow time 1 minute for the cup filling and 4 minutes for the bowl s water flow When the key Last position Spitting position 32 is pressed the d...
Page 21: ...ct the eyes the eyesight protection 41 filters only the blue light used for the resins polimerization and it allows ambient light to pass through Remove the upper lid 16 add 20 to 40 sodium bicarbonate this quantity is enough to meet prophylaxis needs ATTENTION In order to avoid clogging don t add more than 40g of bicarbonate Bicarbonate level can be checked through the transparent lid To adjust t...
Page 22: ... and GLC OPTI Delivery Unit The equipment and the light conductor cannot be placed in the oven or autoclaves The conductor can t be immersed in solvents or substances that contain acetone in its composition Avoid the light conductor to terminal to touch the resin to be polymerized When using the Optilight LD check if the light conductor output doesn t have residues that might obstruct the light be...
Page 23: ...nd dilute it in 500 ml of water 1 to 20 Such solution should be prepared daily IMPORTANT Follow this proportion strictly to avoid damages in the equipment and to have an efficient result in the disinfection Water Scaler Bicarbonate Jet Syncrus GLXF FULL GLXC FULL GLXF GLXC GLF SONIC GLC SONIC GLF JET and GLC JET Delivery Units Remove reservoir 46 unscrewing it anticlockwise and replace water or di...
Page 24: ...th disinfectant Then press the command pedal for some seconds to rinse in order to eliminate the disinfectant residues that could have remained IMPORTANT Repeat this procedure before working day and after each patient Bicarbonate Jet Syncrus GLXF FULL GLXC FULL GLXF GLXC GLF JET and GLC JET Delivery Units Avoid leaving sodium bicarbonate on the reservoir for long periods without using it The air h...
Page 25: ...very Units The light conductor cleaning and the optical protector must be done using only neutral soap and cotton To the exterior of the pen use neutral soap or alcohol 70 vol Never use any other chemical based product than previous mentioned because along the time these products attack the surface of the instrument Never immerse the instrument in disinfection baths Delivery Unit To effect the cle...
Page 26: ...o water from syringe Put filtered water in reservoir Plug compressor in Compressor disconnected No air from syringe Plug compressor in Chair s fuse burned Main or chair switch is off Replace chair s fuse Switch main chair switch on Lack of bicarbonate in rerservoir Spout or reservoir outlet is clogged Bicarbonate excess in reservoir Wrong jet position Bicarbonate jet GLXF FULL GLXC FULL GLXF GLXC ...
Page 27: ...ent care is that concerning spare parts To guarantee the life span of your equipment use only original Gnatus spare parts They are sure to follow the technical specifications and standards required by Gnatus We must also point out to you our chain of authorized dealers Only dealers that make part of this chain will be able to keep your equipment constantly new for they count on technical assistant...