HOW TO USE CONTROL PANEL
1. Job Mode
6. Bursting Timing
2. MIRROR Roller Temp. & Status
7. Counter / Roller Heating Mode
3. EMBO Roller Temp. & Status
8. Feeding Method
4. Paper Length
9. Error Message
5. Roller Speed
Refer to the Explanation of Display for PROTOPIC III-540 for normal conditions.
A. "F:115℃R , R:100℃W" - Roller Temp. & Status Display
MIRROR Roller & EMBO Roller Temp. & its Status.
- F:115℃R : MIRROR Roller Set Temp. & its Status
- R:100℃W : EMBO Roller Set Temp. & its Status
NOTE :
Ready for Lamination status with display of W"(WAIT) or "R"(READY).
NOTE :
Press "MASTER DIAL" to display the current temp. & the roller heater power supply status.
B. Counter Display / Roller Heating Mode Display
To display the power supply status for heater on MIRROR Roller and EMBO Roller.
There are "SINGLE" mode and "DUAL" mode, in "SINGLE" mode, EMBO roller has no heat although temp. is set up.
NOTE :
Refer to TEMP in Explanation of Control Panel to change mode.
[PROTOPIC III-540 DUAL]
2
4
8
5
6
7
3
1
9
Explanation of Display (PROTOPICIII-540DUAL)
A
B