![GMP G 14.25 Installation Manual Download Page 37](http://html1.mh-extra.com/html/gmp/g-14-25/g-14-25_installation-manual_2236380037.webp)
37
G
Line - INSTALLATION MANUAL
GAS SPECIFICATIONS
Correspondence
G
14.25
G
15.35
G
18.35
G
21.35
G
26.35
Nominal heat input
13,6 kW
=
25,6 kW
27 kW
33,5 kW
Gas consumption
G20
G25
G30
G31
1,44 m³/h
1,67 m³/h
1,07 kg/h
1,06 kg/h
=
=
=
=
2,8 m³/h
3,15 m³/h
2,02 kg/h
1,99 kg/h
2,86 m³/h
3,32 m³/h
2,13 kg/h
2,1 kg/h
3,55 m³/h
4,12 m³/h
2,64 kg/h
2,6 kg/h
Nozzle
G20 20 mbar
G25 25 mbar
G25 20 mbar
G20 25 mbar
G30 28...30 mbar G31 30...37 mbar
G31 30 mbar
G30 50 mbar G31 50 mbar
315
315
315
315
180
190
180
=
=
=
=
=
=
=
445
445
445
445
245
265
245
320
320
320
320
180
190
180
350
350
350
350
200
210
200
Manifold pressure (nozzle pressure)
G20 20 mbar
G25 25 mbar
G25 20 mbar
G20 25 mbar
G30 50 mbar G31 50 mbar
10 mbar
15 mbar
15 mbar
10 mbar
28,5 mbar
=
=
=
=
=
10 mbar
15 mbar
15 mbar
10 mbar
28,5 mbar
10 mbar
15 mbar
15 mbar
10 mbar
28,5 mbar
10 mbar
15 mbar
15 mbar
10 mbar
28,5 mbar
Table 6
Correspondence
G
21.50
G
26.50
G
32.50
Nominal heat input
54 kW
67 kW
95,2 kW
Gas consumption
G20
G25
G30
G31
5,7 m³/h
6,65 m³/h
4,26 kg/h
4,2 kg/h
7,09 m³/h
8,25 m³/h
5,28 kg/h
5,21 kg/h
10,08 m³/h
11,72 m³/h
7,5 kg/h
7,4 kg/h
Nozzle
G20 20 mbar
G25 25 mbar
G25 20 mbar
G20 25 mbar
G30 28...30 mbar G31 30...37 mbar
G31 30 mbar
G30 50 mbar G31 50 mbar
320
320
320
320
190
200
190
350
350
350
350
200
215
200
360
360
360
360
250A-230B
260A-240B
250A-230B
Manifold pressure (nozzle pressure)
G20 20 mbar
G25 25 mbar
G25 20 mbar
G20 25 mbar
G30 50 mbar G31 50 mbar
10 mbar
15 mbar
15 mbar
10 mbar
27,5 mbar
10 mbar
15 mbar
15 mbar
10 mbar
28,5 mbar
12 mbar
15 mbar
15 mbar
12 mbar
30 mbar
Table 6A
Gas specifications in Table 6 and 6A are subject to change without notice.
Refer to product serial plate for most updated specifications of product being installed.