32
G
Line - INSTALLATION MANUAL
G
21.35
HEATING
TYPE
Voltage
Wire size
Circuit Breaker Absorption
Electric Power
Heaters Motors
GAS/STEAM
V.230/1/50-60Hz
3 x 2.5 mm² (1Ph + N + )
10 A
5 A
-
1,2/1 kW
ELECTRIC
V.230/3/50-60Hz
4 x 16 mm² (3Ph + )
63 A
62 A
23,4 kW
1 kW
V.400/3N/50-60Hz 5 x 10 mm² (3Ph + N + )
40 A
38 A
23,4 kW
1 kW
V.400/3/50-60Hz
V.440/3/50-60Hz
4 x 10 mm² (3Ph + )
40 A
38 A
23,4 kW
1 kW
Table 3D
G
26.35
HEATING
TYPE
Voltage
Wire size
Circuit Breaker Absorption
Electric Power
Heaters Motors
GAS/STEAM
V.230/1/50-60Hz
3 x 2.5 mm² (1Ph + N + )
10 A
5 A
-
1,2/1 kW
ELECTRIC
V.230/3/50-60Hz
4 x 25 mm² (3Ph + )
80 A
77 A
29,7 kW
1 kW
V.400/3N/50-60Hz 5 x 10 mm² (3Ph + N + )
63 A
44 A
29,7 kW
1 kW
V.400/3/50-60Hz
V.440/3/50-60Hz
4 x 10 mm² (3Ph + )
63 A
44 A
29,7 kW
1 kW
Table 3E
G
21.50
HEATING
TYPE
Voltage
Wire size
Circuit Breaker Absorption
Electric Power
Heaters Motors
GAS/STEAM
V.230/3/50-60Hz
4 x 2.5 mm² (3Ph + )
10 A
7 A
-
2,7/1,6 kW
V.400/3N/50-60Hz 5 x 2.5 mm² (3Ph + N + )
6 A
5 A
-
2,7/1,6 kW
V.400/3/50-60Hz
V.440/3/50-60Hz
4 x 2.5 mm² (3Ph + )
6 A
5 A
-
2,7/1,6 kW
ELECTRIC
V.230/3/50-60Hz
4 x 25 mm² (3Ph + )
125 A
102 A
39 kW
1,6 kW
V.400/3N/50-60Hz 5 x 16 mm² (3Ph + N + )
63 A
62 A
39 kW
1,6 kW
V.400/3/50-60Hz
V.440/3/50-60Hz
4 x 16 mm² (3Ph + )
63 A
62 A
39 kW
1,6 kW
Table 3F