![GMP G 14.25 Installation Manual Download Page 31](http://html1.mh-extra.com/html/gmp/g-14-25/g-14-25_installation-manual_2236380031.webp)
31
G
Line - INSTALLATION MANUAL
ELECTRICAL SPECIFICATIONS
DANGER!
Electrical connections must be carried out by fully qualified engineers.
IMPORTANT!
Circuit connection and protection must be realized in conformity with regional electrical regulations.
Electrical specifications in Table 3 are subject to change without notice.
Refer to product serial plate for most updated specifications of product being installed.
G
14.25
HEATING
TYPE
Voltage
Wire size
Circuit Breaker Absorption
Electric Power
Heaters Motors
GAS
V.230/1/50-60Hz
3 x 2.5 mm² (1Ph + N + )
6 A
2,2 A
-
0,32 kW
ELECTRIC
V.230/3/50-60Hz
4 x 10 mm² (3Ph + )
32 A
31 A
12 kW
0,27 kW
V.400/3N/50-60Hz 5 x 4 mm² (3Ph + N + )
25 A
17,8 A
12 kW
0,27 kW
V.400/3/50-60Hz
V.440/3/50-60Hz
4 x 4 mm² (3Ph + )
25 A
17,8 A
12 kW
0,27 kW
Table 3A
G
15.35
HEATING
TYPE
Voltage
Wire size
Circuit Breaker Absorption
Electric Power
Heaters Motors
GAS/STEAM
V.230/1/50-60Hz
3 x 2.5 mm² (1Ph + N + )
10 A
5 A
-
1,2/1 kW
ELECTRIC
V.230/3/50-60Hz
4 x 10 mm² (3Ph + )
63 A
48 A
18 kW
1 kW
V.400/3N/50-60Hz 5 x 10 mm² (3Ph + N + )
32 A
29 A
18 kW
1 kW
V.400/3/50-60Hz
V.440/3/50-60Hz
4 x 10 mm² (3Ph + )
32 A
29 A
18 kW
1 kW
Table 3B
G
18.35
HEATING
TYPE
Voltage
Wire size
Circuit Breaker Absorption
Electric Power
Heaters Motors
GAS/STEAM
V.230/1/50-60Hz
3 x 2.5 mm² (1Ph + N + )
10 A
5 A
-
1,2/1 kW
ELECTRIC
V.230/3/50-60Hz
4 x 16 mm² (3Ph + )
63 A
55 A
20,7 kW
1 kW
V.400/3N/50-60Hz 5 x 10 mm² (3Ph + N + )
32 A
31,5 A
20,7 kW
1 kW
V.400/3/50-60Hz
V.440/3/50-60Hz
4 x 10 mm² (3Ph + )
32 A
31,4 A
20,7 kW
1 kW
Table 3C