![GMP Breeze 89010 Operation & Maintenance Manual Download Page 37](http://html.mh-extra.com/html/gmp/breeze-89010/breeze-89010_operation-and-maintenance-manual_2236405037.webp)
Page 37 of 42
General Machine Products (KT), LLC
3. APPENDIX 3
Programming Parameters for CUB5B counter/rate meter fitted to Breeze machines—
Nov 2005 Onwards.
The device must be wired and installed into the machine prior to programming.
Breeze is fitted with C-M-DEV-CUB5B, backlight version.
The DIP switch positions are as follows:
1 OFF
2 OFF
3 OFF
4 OFF
Please see the attached CUB5 Programming
Overview attached to this document.
a. Press and hold SEL for 2 seconds to enter
programming mode
b. Enter the Pro-Code-111 (a general code of 222 may also work)
c. Press and Hold SEL for 2 seconds
d. Pro-no should now be flashing, press RST
e. Press RST to move through the various sections 1-input, 2-rate etc.
f. Press SEL to enter that section
g. To change the value of a parameter press RST
h. Press SEL to move to the next parameter
i. When all the parameters in the section have been scrolled through you will return to the
Pro-no display, press RST to scroll to another section else press SEL to exit programming
mode.
DIP Switch
CUB5B counter/rate meter