Electrical System
5. Loose or broken wire from connector 12S01 pin
2 to right and/or left motor brake brake connector
2P04 and/or 2P05 pin 2
6. Loose or broken 24V- wire from right and/or left
motor brake brake connector 2P04 and/or 2P05
pin 1 to 12S01 connector pin 11
7. Loose or broken 24V- wire from connector 12P01
connector pin 11 to pin 12 and connector 8S02
pin 1
8. Loose or broken 24V- wire from connector 8P02
pin 1 to battery -
9. Defective right and or left motor brake
10. Loose or defective wiring from TS200 machine
controller M1 + to right and/or left drive motor
11. Loose or defective wiring from TS200 machine
controller M1- to right and/or left drive motor
12. Defective traction motor
Section 4 - Troubleshooting Information
Check continuity. Replace if defective.
Check continuity. Replace if defective.
Check continuity. Replace if defective.
Check continuity. Replace if defective.
Check brakes. Replace if defective.
Check continuity. Replace if defective.
Check continuity. Replace if defective.
Check Motors. Replace if defective.
45