Getting Started
G
Remove the pump by turning it to the left.
Before doing this release pump rods, turn
them 180° and transmit the srew force via
the back of the zwistlocks on the pump hous-
ing.
G
Filling of the container.
G
Re-insert pump and tighten.
G
Pump up the unit. Observe the safety /
pressure relief valve
(A)
during pumping.
Peak pressure is reached when the safety /
pressure relief valve is triggered. Any ex-
cess pressure will escape through the
safety / pressure relief valve.
G
Press down the lever of the quick-action
valve to spray.
G
Pump up the unit again once the pressure
has dropped to around 1.5 bar so as to
ensure a consistent distribution of the
sprayed liquid.
Emptying and Service
G
Any residual pressure in the tank can be
vented by lifting up the knob on the safety /
pressure relief valve
(A)
.
G
Unscrew the pomp carefully, at first only a
few turns by left-hand rotation, so that com-
pressed air being still in the tank can escape.
Only then unscrew the pump completely and
take it out of the tank.
G
Empty and wash out the unit after use.
Note!
Any remaining liquid in the tank
can be emptied out completely through
the filler opening. The type of flushing
liquid to be used and how it is to be dis-
posed of will depend on the details given
by the manufacturer of the liquid to be
sprayed. Also consider whether the tank
is resistant to the flushing liquid.
G
The pump will last much longer if the
pump O-ring
(E)
is lubricated from time to
time with a little resin- and acid-free
grease.
G
Dismantle by pulling the piston rod with the
O-ring
(E)
, and the pump handle
(F)
fully up-
wards, clicking it into the guide stopper
(G)
,
and turning it about 1/8th of a turn anti-
clockwise.
16
GB
WARNING!
Health risk through leaking cleaning
fluid!!
A leaking device or leaking components may
result in draining or spouting of cleaning fluid.
For this reason, observe the following safety
instructions:
-
Check that the unit is in perfect condition
and properly sealed each time before use.
Pull up the safety / pressure relief valve
(A)
by hand and check that it returns to the
starting position.
- Only operate or move device when standing
or hanging upright.
- Inspect all screw joints for tight fitting.
WARNING!
Contact with cleaning fluids poses a
health risk.
Observe the max. filling amount (see
Technical Data) and the correct dosing given
by the spray producer.