G
In practice, sprayed liquids are a mixture of
various substances whose composition is
only known to the manufacturer. The suit-
ability of the unit for a specific liquid must
therefore be determined before use by the
user in conjunction with the manufacturer
of the substance. The following is a basic
guide for the upper limits for more detailed
testing of acids or alkalis:
- nitric acid, acetic acid and propionic acid
up to 10%
- hydrochloric acid up to 10%, limited to
brief use only
- phosphoric and sulphuric acid up to 30%
- caustie potash and caustie soda up to
20%
Foreseeable misuse
G
The device is
not
suitable for:
- formic and hydrofluoric acid in any
concentration.
- acids and alkalis at concentrations
greater than the amounts quoted or
as mixtures.
- oils and fuels.
- wetting agents (surfactants) that cause
or could promote the formation of cracks
in the plastics used.
- liquids at temperatures over + 30°C.
- inflammable liquids with a flash point
below + 55°C.
- very tenacious or sticky liquids, or liquids
that leave residues, which cannot be
completely poured or flushed out of the
unit (oils and oil-bearing liquids).
G
On request, the manufacturer of the unit
can make available a detailed list of the
materials used in the parts of the unit for
more detailed examination.
G
Unauthorised changes to the unit made by
the user or inappropriate use shall render
null and void the liability of the manufac-
turer for any damage caused as a result.
Assembling instructions
G
Fig.
:
Install the spray tube into the
quick-action valve.
G
Fig.
:
Screw the hose into the quick-ac-
tion valve.
G
Fig.
:
Guide the diagonally-cut riser
tube
1
into the small connecting hole in the
cover of the tank and press it down firmly.
Push the hose connecting nut up to the first
thread of the connector and tighten it up
carefully. Finally, press the hose into the hose
holder
2
in the filler funnel.
G
Fig.
: CM 50/80
Insert the safety / pressure relief valve into
the large connecting hole in the cover of the
tank and tighten it up carefully.
Assembly of carrying strap : CM 50
G
Fig.
:
Carrying strap to be fixed onto
suspension hooks of the tank with the inside
punchings. In order to secure the hold, the
excess end is to be bended and fixed with the
outside punchings.
Assembly of carrying strap : CM 80
G
Fig.
E
D
C
B
A
A
15
GB