19 / 28
Press to select ALU2
☆
mode.
This is the combination application: clip-on weight inside and attach the adhesive weight on rim.
Measure the dimensions as shown in the diagram (Fig. 22).
Pay attention to press to memorize A1 dimension which should be measured at first, then
measure AE dimension which will be memorized automatically.
Fig. 22
Press
After performing the balancing spin, manually rotate the wheel to the unbalance position to clip on the
weight inside, then pull the gauge to the outer position until “0” is shown on the digital readouts,
where to apply the adhesive weights
Fig. 23
For an example
A1 = 92
AE = 241
dI = 13.5
dE = 12.5
Rotate wheel to the unbalance
position manually to clip on the
weight on the rim.