Several input affecting settings such as delays, backup-call and direction of operation can
be set input-specificly.
Input 1
Message format::
(01=aa,b,c)
(01=aa,b,c)
(01=aa,b,c)
(01=aa,b,c)
aa = entry / exit delay, 0-99 seconds
b = backup call, 0=no 1=yes
c = direction of operation, 0=N.C 1=N.O
Input 2
Message format::
(02=aa,b,c)
(02=aa,b,c)
(02=aa,b,c)
(02=aa,b,c) ;settings for input 2
aa = response time, 0-99 seconds
b = backup call, 0=no 1=yes
c = direction of operation, 0=N.C 1=N.O
Example: (02=05,1,1)
(02=05,1,1)
(02=05,1,1)
(02=05,1,1)
Input 2 is set with a 5 second response time (the alarm is registered after the input has
been 5 seconds consecutively in alarming state), the backup call feature is activated and
the direction of operation is set to N.O (normally open).
6
6
6
6.5
.5
.5
.5 Inputs that follow arm/disarm event
Inputs that follow arm/disarm event
Inputs that follow arm/disarm event
Inputs that follow arm/disarm event
If the arm/disarm function by phone call is set (see 6.9 General settings), this parameter
determines the inputs that are affected by the arm / disarm event.
Message format:
(09=a,b)
(09=a,b)
(09=a,b)
(09=a,b)
a,b
a,b
a,b
a,b = controlled inputs
Example: (09=2)
(09=2)
(09=2)
(09=2)
Input 2 is set to follow the arm / disarm state. Input 1 is in this case always armed.