2

Correct pre-charge is required for proper tank performance.

  Any adjustments to the factory pre-charge must be done 

prior to initial tank installation and with zero pressure on the system. 

This pressure tank is shipped from the factory with a pre-charge of 38 psi. 

 

   

 

 

         

1. For tanks installed with a fixed speed pumping system with a differential pressure set up to 30 psi, the pre-charge should be 
set to 2 psi below the cut-in pressure.  (

Example:

 In a 20/40 pressure switch, the tank is set to 18 psi; a 30/50 pressure switch, 

tank is set to 28 psi; and a 40/60 pressure switch, tank is set to 38 psi.) 

    

 

 

         

2. For tanks installed with a pump controlled by a pressure switch with a pressure differential greater than 30 psi, electronic 
controls or variable speed controls, the pre-charge should be set to 65% of the maximum system pressure. 

 

 

 

         

3. For tanks installed on mains pressure, the tank pre-charge should be set equal to the system pressure. If the system pressure 
exceeds 88 psi then a suitable pressure reducing valve should be installed.

TO ADJUST TANK PRE-CHARGE PRIOR TO INSTALLATION

• Remove the protective cap from the air valve. 

 

 

 

 

 

 

• Check the tank pre-charge pressure using a suitable pressure gauge. 

 

 

 

 

• If required, add air at ambient temperature to the tank using a manual pump or air compressor until the proper pre-charge    
 

 

 

pressure 

is 

reached. 

        

• Replace the protective cap on the air valve.

TO ADJUST TANK PRE-CHARGE AFTER INSTALLATION (IF REQUIRED) 

• Disconnect all power to the system pump. 

 

 

 

 

 

 

• Drain the tank of water by opening a faucet or drain valve. 

 

 

 

 

 

• Add or release air at ambient temperature, if required, using a manual pump or air compressor until the proper pre-charge  
  pressure is reached.

INSTALLATION LOCATION

ADJUSTING TANK PRE-CHARGE

PRESSURE TANK INSTALLATION

In order to ensure your tank provides its maximum service life, it should be installed in a covered, dry area that is not subject to 
freezing. This tank must not be installed in a location where it can rub against a hard surface such as a wall.
The tank should always be located downstream from the pump. If the tank is located at a lower elevation than the demand, a 
check valve must be installed.

The tank should be located as close as possible to the system pressure switch, transducer or flow sensor to reduce the 
negative effects of added friction loss and/or differences in elevation between the tank and these components. 

This tank has been designed to be mounted on a level surface and must be adequately supported around the entire base using 
the mounting holes or brackets provided.  Inline tanks should be connected directly to the pump or the supply line using a 3- or 5- 
way fitting. 

ACCESSORIES NEEDED

Pressure Gauge

Pressure Switch

Check Valve Drain Valve

Teflon ™ Tape

Tank Connector  Fitting

Pressure Relief Valve

DO NOT ADJUST THE PRE-CHARGE OF THE PRESSURE TANK WITH THE SYSTEM UNDER PRESSURE.

Do not adjust the tank air pressure if there are any visible signs of corrosion on the tank. If this pressure tank 

shows any visible signs of corrosion or rusting, the tank must be replaced immediately. Failure to follow these 

instructions may result in serious injury, death and/or property damage.

The tank must be installed in a suitable location to prevent water damage due to leaks and 

have adequate drainage.  The manufacturer is not liable for any water damage that occurs in 

association with tank installation or failure.

IN NO EVENT SHOULD THE TANK PRE-CHARGE EXCEED 80 PSI.

TOOLS NEEDED

Adjustable Wrench

Adjustable Pliers

Screwdriver

Tire Pressure Gauge

Tape Measure

Hacksaw

Pipe Wrench

Summary of Contents for PressureWave

Page 1: ...alaci n y Operaci n Manuel d installation et d utilisation PressureWave and PressureWaveSF PressureWaveTM y PressureWave SFTM PressureWaveMC et PressureWaveSFMC GWS USA Bradenton FL USA support gwsusa...

Page 2: ...must be protected by a suitable pressure relief valve set at a maximum of 100 psi This pressure tank is shipped with a pre charge of 38 psi and any adjustment to the pre charge must be done prior to...

Page 3: ...NSTALLATION LOCATION ADJUSTING TANK PRE CHARGE PRESSURE TANK INSTALLATION In order to ensure your tank provides its maximum service life it should be installed in a covered dry area that is not subjec...

Page 4: ...dance with prevailing local codes and standards Inspect the installation for water leaks paying close attention to the connection between the pressure tank and the system piping The pressure tank shou...

Page 5: ...GLOBAL WATER SOLUTIONS USA LIMITED PRODUCT WARRANTY Always release all water and air from tank before disassembling the parts exposed to pressure such as flanges air valve pressure gauge and the like...

Page 6: ...ess of whether there is or there is shown to have been a defect in materials or workmanship negligence in manufacture or design or a failure to warn GWS USA s liability arising out of the sale or deli...

Page 7: ...emplazarse inmediatamente si estos signos est n presentes El incumplimiento de estas instrucciones puede provocar lesiones graves la muerte y o da os a la propiedad e invalidar la garant a del product...

Page 8: ...Cinta de Tefl n Accesorio Conector de Tanque GWS USA Bradenton FL USA support gwsusa com 833 261 5461 www gwsusa com 2020 Rev 02 25 PARA AJUSTAR LA PRECARGA DEL TANQUE antes de la instalaci n Retire...

Page 9: ...ara permitir que se purgue el aire de la tuber a del sistema Encienda la energ a de alimentaci n del suministro de agua la bomba deber a encenderse llenando la tuber a del sistema Cuando el agua fluya...

Page 10: ...DUCTO GLOBAL WATER SOLUTIONS USA GWS USA PRODUCTOS CUBIERTOS PRESSURE WAVE Series LX LH and LV Tanque PRESSURE WAVE SF Series LV Tanque IMPORTANTE Lea atentamente el manual de instrucciones de instala...

Page 11: ...que tiene la culpa e independientemente de si existe o no se ha demostrado que hubo un defecto en los materiales o la mano de obra negligencia en la fabricaci n o dise o o una falla en la advertencia...

Page 12: ...e r gl e un maximum de 100 lb po Ce r servoir sous pression est exp di avec une pr charge de 38 lb po et tout r glage de la pr charge doit tre effectu avant l installation temp rature ambiante Ne pas...

Page 13: ...arge appropri e EMPLACEMENT D INSTALLATION R GLAGE DE LA PR CHARGE DU R SERVOIR INSTALLATION DU R SERVOIR SOUS PRESSION Afin de garantir la dur e de vie maximale de votre r servoir il faut l installer...

Page 14: ...ventuelles d eau en portant une attention particuli re au raccord entre le r servoir sous pression et la tuyauterie du syst me Le r servoir sous pression doit tre install sur la conduite d alimentatio...

Page 15: ...rides la soupape d air le manom tre etc Pour confirmer la pr charge couper l alimentation de la pompe isoler et vidanger le r servoir V rifier la pr charge l aide d un manom tre Si n cessaire pomper d...

Page 16: ...endamment du fait qu il y ait ou non un d faut de mat riaux ou de fabrication une n gligence dans la fabrication ou la conception ou un manque d avertissement La responsabilit de GWS USA d coulant de...

Page 17: ...16...

Reviews: