background image

1

OPERATION

This pressure tank has been designed to store and deliver 
potable water under pressure in a domestic water system. 
It features a diaphragm or membrane design that keeps the 
system water in a safe and contaminant-free chamber for 
pressurized water supply between pump cycles.
Without a pressurized storage tank, a domestic water system’s 
pump would turn on every time there is a demand for water, 
even if the demand is small. This frequent on/off cycling shortens 
the useful life of the pump. Pressure tanks are designed to store 
water when the pump is running and then deliver pressurized 
water to the system when the pump is shut off (See Fig. 1). A 
properly sized tank will store at least one gallon of water for 
every gallon per minute (GPM) of pump capacity. This allows for 
fewer pump starts and longer run times which maximizes the life 
and efficiency of the pump system.

These instructions have been prepared to acquaint you with 
the correct method of installing and operating your GWS 
pressure tank.  Please read and follow these instructions and 
heed any warnings to ensure safety and maximum product 
performance.  In the event of installation difficulties or need for 
further advice, please contact the nearest GWS sales office or 
dealer.  

The following instructions and warnings are subject to 
periodic updates and should be regularly reviewed on 
the website www.gwsusa.com/support for important 
safety information and instruction updates.

PLEASE READ ALL INSTRUCTIONS AND 

WARNINGS BEFORE INSTALLING YOUR 

NEW GLOBAL WATER SOLUTIONS PRES-

SURE TANK

GWS USA, Bradenton, FL, USA  • [email protected]  • (833) 261-5461  •  www.gwsusa.com  •  2020 Rev. 02.25

EN

PressureWave

TM  

and PressureWave SF

TM

 Series Pressure Tanks

COMPLIANCE TO CODES

  

 

This pressure tank must be installed by a 

qualified professional following all local and national plumbing 
and electrical codes. The tank must be annually inspected for 
visible signs of damage, corrosion, or leakage and replaced 
immediately if these signs are present. 

Failure to follow 

these instructions and codes may result in serious 

injury, death and/or property damage and will void the 

product warranty.

EXPLOSION HAZARD 

 

This pressure tank is designed for water 

storage at a maximum pressure of 150 psi and a maximum 
temperature of 194° F. 

The system must be protected by 

a suitable pressure relief valve set at a maximum of 100 

psi.

 This pressure tank is shipped with a pre-charge of 38 

psi and any adjustment to the pre-charge must be done prior 
to installation and at ambient temperature. Do not adjust the 
pre-charge of this tank if the product is corroded or damaged 
or shows any signs of diminished integrity. The maximum 
allowable pre-charge in this pressure tank is 80 psi. 

Failure 

to follow these instructions may result in serious injury, 

death and/or property damage.

PRO PE R PL AC E M E N T O F TA N K 

This pressure tank should be installed 

in a covered, dry area.  This tank must not be installed in 
a location that is subject to freezing or where it can rub or 
vibrate against a hard surface.  The tank must be installed in 
a suitable location to prevent water damage due to leaks and 
have means for adequate drainage. 

The manufacturer of 

this product is not liable or responsible for any water 
damage associated with the installation and/or failure 
of this product. Failure to follow these instructions may 
result in serious injury, death and/or property damage.

FOR POTABLE WATER USE ONLY  

This pressure tank is intended for use 

with potable water systems only. Use with non-potable water 
or any other fluid may be dangerous and will void the warranty. 
This product’s performance and lifespan can significantly be 
impacted by aggressive water conditions. A water test should 
be conducted specifically looking for corrosive water, acids 
and other relevant water contaminants which, if present, must 
be treated appropriately. The system piping must be properly 
grounded to earth. A dielectric union may be required in the 
system. 

Failure to follow these instructions may result in 

serious injury, death and/or property damage.

C A L I F O R N I A  P R O P O S I T I O N  6 5 

WARNING! 

This product contains a 

chemical known to the State of California, if exposed, to 
have the potential to cause cancer, birth defects or other 
reproductive harm. (California installer – California law requires 
that this notice be given to the consumer/end user of the 
product). For more information, see Prop 65 details at www. 
P65warnings.ca.gov.

THIS IS A SAFETY ALERT SYMBOL. IT IS USED TO ALERT YOU 

TO POTENTIAL PERSONAL INJURY HAZARDS. OBEY ALL 

SAFETY MESSAGES THAT FOLLOW THIS SYMBOL TO AVOID 

POSSIBLE INJURY OR DEATH.

INDICATES A POTENTIALLY HAZARDOUS SITUATION WHICH, 

IF NOT AVOIDED, COULD RESULT IN SERIOUS INJURY, DEATH, 

AND/OR SIGNIFICANT PROPERTY DAMAGE.

FIG. 1

Summary of Contents for PressureWave

Page 1: ...alaci n y Operaci n Manuel d installation et d utilisation PressureWave and PressureWaveSF PressureWaveTM y PressureWave SFTM PressureWaveMC et PressureWaveSFMC GWS USA Bradenton FL USA support gwsusa...

Page 2: ...must be protected by a suitable pressure relief valve set at a maximum of 100 psi This pressure tank is shipped with a pre charge of 38 psi and any adjustment to the pre charge must be done prior to...

Page 3: ...NSTALLATION LOCATION ADJUSTING TANK PRE CHARGE PRESSURE TANK INSTALLATION In order to ensure your tank provides its maximum service life it should be installed in a covered dry area that is not subjec...

Page 4: ...dance with prevailing local codes and standards Inspect the installation for water leaks paying close attention to the connection between the pressure tank and the system piping The pressure tank shou...

Page 5: ...GLOBAL WATER SOLUTIONS USA LIMITED PRODUCT WARRANTY Always release all water and air from tank before disassembling the parts exposed to pressure such as flanges air valve pressure gauge and the like...

Page 6: ...ess of whether there is or there is shown to have been a defect in materials or workmanship negligence in manufacture or design or a failure to warn GWS USA s liability arising out of the sale or deli...

Page 7: ...emplazarse inmediatamente si estos signos est n presentes El incumplimiento de estas instrucciones puede provocar lesiones graves la muerte y o da os a la propiedad e invalidar la garant a del product...

Page 8: ...Cinta de Tefl n Accesorio Conector de Tanque GWS USA Bradenton FL USA support gwsusa com 833 261 5461 www gwsusa com 2020 Rev 02 25 PARA AJUSTAR LA PRECARGA DEL TANQUE antes de la instalaci n Retire...

Page 9: ...ara permitir que se purgue el aire de la tuber a del sistema Encienda la energ a de alimentaci n del suministro de agua la bomba deber a encenderse llenando la tuber a del sistema Cuando el agua fluya...

Page 10: ...DUCTO GLOBAL WATER SOLUTIONS USA GWS USA PRODUCTOS CUBIERTOS PRESSURE WAVE Series LX LH and LV Tanque PRESSURE WAVE SF Series LV Tanque IMPORTANTE Lea atentamente el manual de instrucciones de instala...

Page 11: ...que tiene la culpa e independientemente de si existe o no se ha demostrado que hubo un defecto en los materiales o la mano de obra negligencia en la fabricaci n o dise o o una falla en la advertencia...

Page 12: ...e r gl e un maximum de 100 lb po Ce r servoir sous pression est exp di avec une pr charge de 38 lb po et tout r glage de la pr charge doit tre effectu avant l installation temp rature ambiante Ne pas...

Page 13: ...arge appropri e EMPLACEMENT D INSTALLATION R GLAGE DE LA PR CHARGE DU R SERVOIR INSTALLATION DU R SERVOIR SOUS PRESSION Afin de garantir la dur e de vie maximale de votre r servoir il faut l installer...

Page 14: ...ventuelles d eau en portant une attention particuli re au raccord entre le r servoir sous pression et la tuyauterie du syst me Le r servoir sous pression doit tre install sur la conduite d alimentatio...

Page 15: ...rides la soupape d air le manom tre etc Pour confirmer la pr charge couper l alimentation de la pompe isoler et vidanger le r servoir V rifier la pr charge l aide d un manom tre Si n cessaire pomper d...

Page 16: ...endamment du fait qu il y ait ou non un d faut de mat riaux ou de fabrication une n gligence dans la fabrication ou la conception ou un manque d avertissement La responsabilit de GWS USA d coulant de...

Page 17: ...16...

Reviews: