INSTALLATION
UNPACKING
Immediately after unpacking the dishwasher, check it for possible shipping damage.
If this machine is found to be damaged after unpacking, save the packaging material
and contact the carrier within 3 days from date of delivery.
Prior to installation, verify that the electrical service agrees with the specifications on
the machine data plate, which refer to the operation and services manual
After unpacking the dishwasher, remove the items shipped uninstalled (overflow
tube, pump intake strainer, curtains, and chamber hole plug kit) and instruction
manual inside the machine. Set the dishwasher in its proper location. Adjust the
height and level by turning the adjustable feet. NOTE: The dishwasher must be
positioned and leveled before making plumbing connections.
ASSEMBLY
Dish tables should be fitted into the dishwasher. Use Mastic between table and lip of
tank to prevent leakage. Rack track height should be from 4 mm to 6 mm above the
tank lip. Dish tables should be sloped so that any water carried from the dishwasher
will drain back into it.
PLUMBING CONNECTIONS
WARNING:
PLUMBING
CONNECTIONS
MUST
COMPLY
WITH
APPLICABLE SANITARY, SAFETY, AND PLUMBING CODES.
The plumber who connects this machine is responsible for making certain that both
water and steam lines are THOROUGHLY FLUSHED OUT BEFORE connecting to
any manual valve or solenoid valve.
Manual valves or solenoid valves fouled by foreign matter, and any expenses
resulting from this fouling, are NOT the responsibility of the manufacturer.