Global-Tek (Singapore) Pte Ltd
Page 5
An over-heat protector is also provided for electric heater. If overheating occurred,
the heat supply will be turned off . Turn the POWER switch OFF and contact your
authorized service office.
Booster Protection
The booster water temperature is regulated by two thermostats to keep the rinse
water temperature between 82-95
℃
. The thermostats are preset at the factory and no
adjustment is needed. If necessary, contact your local authorized service office.
WARNING:
The breaker is preset to “OFF” at the factory. Do not turn on the
breaker until all the tanks and boosters filled with water by activating the machine
auto fill.
Only
turn the breaker on after all tanks are filled, otherwise, the booster
tank & its heating elements will be damaged !!
Rinse Booster
Booster heater is equipped with 4 x 9 Kw heating elements.
Wash/Auto-timer Actuator and Rinse Actuator
Wash actuator, which is located at the entrance of the machine, works only when the
timer is turned to AUTO. When the rack enters into the machine, wash begins. When
timer is on MANUAL the switch does not function.
The rinse actuator is located at the exit of the machine. Rack contact with the rinse
actuator activates the final rinse.
Door Interlock
Door interlock switches will prevent machine operation while an inspection door is
open during the machine is operating, the wash motors and conveyor motor will
automatically turn off. After the door is closed, the machine must be restarted by
pushing the MOTOR switch to ON.