Error Code
CDU Error Code Description and Diagnostics
1. Check solenoid for interference.
2. Check gate for damage or interference.
3. Check encoder for blockage and swinging lever for damage or interference.
4. Check cable form main B/D to solenoid for damage or loose connector.
5. Check cable from main B/D to encoder for damage or loose connector.
6. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty <YELLOW CABLE>
Normal range of 2~5 V when blocked <YELLOW CABLE>
7. Replace encoder when the voltage is not in the normal range.
8. Replace Main B/D.
C0058
Note count mismatch (# note at CST exit < # note at count)
1. Check cables from main B/D to sensor for proper connection.
2. Replace Main B/D.
C0059
Note jam occurred while initializing
1. Check note path for jam.
2. Check note for interference or blockage.
3. Check belt for proper engagement.
4. Replace CDU.
C005B
2nd cassette failure to pick up
1. Check note inside cassette for interference by foreign object.
2. Check gears inside cassette for debris between gear teeth.
3. Check rollers inside cassette for damage.
4. Check push plate for interference.
5. Check cassette exit path for blockage.
6. Replace cassette.
C0060
3rd cassette exit sensor (K) blocked after dispensing
1. Check sensors RIGHT/LEFT for blockage.
2. Check to ensure sensor is working properly.
3. Check cable from sensor to main B/D for damage or loose connector.
4. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
5. Replace Inlet sensor when the voltage is not in the normal range.
6. Replace main B/D.
C0062
3rd cassette exit sensor (K) blocked
1. Check sensors RIGHT/LEFT for blockage.
2. Check to ensure sensor is working properly.
3. Check cable from sensor to main B/D for damage or loose connector.
4. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
5. Replace Inlet sensor when the voltage is not in the normal range.
6. Replace main B/D.
C006A
Note from 2nd CST not arriving at double timing sensor (H)