background image

 

CHAPTER SIX: WARRANTY, FACTORY REPAIR AND SAFETY 

 

6.1. Warranty 
Any product, or part thereof, manufactured by Glentek, Inc., described in this manual, 
which under normal operating conditions, in the plant of the original purchaser, thereof 
proves defective in material or workmanship within one year from the date of shipment by 
us, as determined by an inspection by us, will be repaired or replaced free of charge, FOB 
our factory, El Segundo, California, U.S.A. provided that you promptly send to us notice of 
the defect and establish that the product has been properly installed, maintained, and  
operated within the limits of rated and normal usage, and that no factory sealed  
adjustments have been tampered with.  Glentek's liability is limited to repair or  
replacement of defective parts.  

 

Any product or part manufactured by others and merely installed by us, such as an electric 
motor, etc., is specifically not warranted by us and it is agreed that such product or part 
shall only carry the warranty, if any, supplied by the manufacturer of that part.  It is also 
understood that you must look directly to such manufacturer for any defect, failure, claim 
or damage caused by such product or part.  

 

Under no circumstances shall Glentek, Inc. or any of our affiliates have any liability 
whatsoever for claims or damages arising out of the loss of use of any product or part sold 
to you.  Nor shall we have any liability to yourself or anyone for any indirect or 
consequential damages such as injuries to person and property caused directly or 
indirectly by the product or part sold to you, and you agree in accepting our product or part 
to save us harmless from any and all such claim  
 
6.2. Factory  Repair 
Should it become necessary to return a vector drive to Glentek for repair, please follow 
the procedure described below:  

1.         Reassemble the unit, if necessary, making certain that all the hardware is 
            in place.  
2.       Tag the unit with the following information:  

A. Serial number and model number.  
B. Company name, phone number, and name of representative 

returning the unit.  

C. A brief notation explaining the malfunction.  
D. Date the unit is being returned.  

3.         Repackage the unit with the same care and fashion in which it was re-

ceived. Label the container with the appropriate stickers (e.g.: FRAGILE: 
HANDLE WITH CARE).  

4.         Contact a Glentek representative, confirm that the unit is being returned 
            to the factory and obtain an RMA (Return Material Authorization) number. 
            The RMA number must accompany the unit upon return to Glentek.  

 

16 

 

Summary of Contents for SMB9675-1A-1

Page 1: ...L Model SMB9675 1A 1 MANUAL 9675 1040 000 REVISION B DATE 9 Sep 2011 FADAL REPLACEMENT SENSORED VECTOR DRIVE SENSORLESS INVERTER DRIVE Fadal is a trademark of Fadal Machining Centers we have no affili...

Page 2: ......

Page 3: ...Cable 8 3 3 3 Control Cable 8 3 3 4 Wye Delta Cable 8 3 3 5 Encoder Feedback Cable 8 3 3 6 Rigid Tap Cable Encoder Output 8 CHAPTER FOUR SETUP AND TUNING 4 1 Turning the power on 10 4 2 Establishing...

Page 4: ...and Signal 22 Controller Inputs Outputs 22 Encoder Feedback 24 Encoder Output 24 Load Meter Output 24 PC Interface 25 Power Input and Motor Output 26 DRAWINGS DIAGRAMS FADAL Vector Drive Installation...

Page 5: ...control down to and including zero speed of an induction motor The SMB9675 1A 1 vector drive can operate in sensorless mode no feedback is needed This mode of operation is usually referred to as inver...

Page 6: ...LDOR 15HT 7 5K YD 7500 15 SMB9675 1A 1 7090 INV 0044 VECTOR BALDOR 10HP 7 5K YD CE 7500 10 SMB9675 1A 1 7090 INV 0045 VECTOR BALDOR 10HP 7 5K YD 10K 7 5K 10 SMB9675 1A 1 7090 INV 0046 VECTOR BALDOR 15...

Page 7: ...ALDOR 10HP 10K NCL NON RT 10000 10 SMB9675 1A 1 7091 INV 0054 INVERTER BALDOR 15HT 10K NCL NON RT 10000 20 SMB9675 1A 1 7091 INV 0057 INVERTER BALDOR 5HP 6500RPM 6POLE 6500 5 SMB9675 1A 1 7091 INV 003...

Page 8: ...l work with Glentek Inc vector or VFD drives earlier versions are not compatible 2 2 3 Installation The MotionMaestro install disk is set up to utilize Install Shield to simplify installation There ar...

Page 9: ...cable has a female DB 9 computer on one end and an RJ 45 vector drive on the other 2 3 2 USB Port If your PC has a USB port a USB to serial port RS 232 adapter GTK GC2410 001 is necessary in addition...

Page 10: ...ecting the AC regenerative braking motor and green ground wires Match the wire labels to the terminal block labels Check connections for tightness See the Appendix A for more details 3 3 2 Load Meter...

Page 11: ...Before and after photos of a typical installation 9...

Page 12: ...se the procedures as follow for reference 4 1 Turning the Power On Carefully recheck the wiring Restore power to the VMC After the VMC is finished initializing check the vector drive status 7 segment...

Page 13: ...motor to be used The Nominal DC Bus is preset to 325VDC Motor Safety Limits Verify that the value is same as motor rating Vector Control Parameters Verify that the parameters are correct and match th...

Page 14: ...amplifier the parameters need to be saved to NVM Non Volatile Mem ory The saving sequence is amplifier model part number dependent Refer to the appropriate amplifier model part number below for the ne...

Page 15: ...tenance manual Install test screw SVT 0077 The screw can be fabricated from 1 000 round stock by threading a 14 TPI Acme thread Program is for Format 1 Use test program 6000 or the following program N...

Page 16: ...the SINGLE STEP key Be sure the test screw returns to its original position Set the indicator as shown below the tip must be touching the lower thread halfway into the thread the second thread from th...

Page 17: ...450VDC Regenerative braking circuit not working regen resistor does not match spindle check fuse in regen circuit C Clamp Disabled Vector drive disabled Control is disabling the drive E Encoder Fault...

Page 18: ...ge caused by such product or part Under no circumstances shall Glentek Inc or any of our affiliates have any liability whatsoever for claims or damages arising out of the loss of use of any product or...

Page 19: ...n charged after the power is shutoff Wait 5 minutes to allow the capacitors to discharge before removing the cover or working on the drive Be sure the system is properly grounded before applying power...

Page 20: ...LINE 1 three phase AC input 2 Input L2 AC LINE 2 three phase AC input 3 Input L3 AC LINE 3 three phase AC input 4 Rsvd Reserved Reserved 5 Rsvd Reserved Reserved 6 Output B DC BUS Return output 7 Inpu...

Page 21: ...unction 1 Input Spindle Common Spindle Common for Forward Reverse 2 Input Spindle Reverse Spindle Reverse 3 Input Spindle Forward Spindle Forward 4 Input CMD Common CMD Common for Fault Speed 5 Input...

Page 22: ...nal wiring 22 AWG 0 326 mm2 or larger 105 C rated PVC or better Connector Description Type 5 Pin Terminal Block Terminal Block 5 Position 22 12 AWG Phoenix Contact 1934890 Designations Pin I O Name Fu...

Page 23: ...acters will be displayed as is appropriate to the fault or state Note See Chapter 5 for more information on Amplifier status codes Controller Input and Output Signals Signals that typically are connec...

Page 24: ...rection If both signals are on the signals are pulled low motor movement in both directions is enabled When only one enable is closed FORWARD or REVERSE on the velocity command is unipolar and when bo...

Page 25: ...O pin at the amplifier A spindle FAULT is de clared by the spindle drive Status good is 10 VDC thru a 1K pull up resistor 0 VDC indicates a fault condition to the CNC The Fault output is open collecto...

Page 26: ...of up to 10 MHz is possi ble but is system dependent The Z channel is edge sensitive such that swapping Z and Z does not change the behavior of the amplifier Encoder Output The encoder out signals are...

Page 27: ...ector Note If required Glentek can customize a serial port digital interface to adapt to your controller as re quired to meet your protocols We are currently doing this for high speed Ethernet ports 2...

Page 28: ...VDC 5 R1 and R2 are external Regen resistor brake inputs Acceptable resistance range is 12 30 Ohms Regen turns on at 430 VDC 5 Regen circuit uses a Ferraz Shawmut TRS10R time delay fuse Motor power is...

Page 29: ...27 Fadal is a trademark of Fadal Machining Centers we have no affiliation with Fadal or Mag IAS...

Page 30: ...28...

Page 31: ...29...

Page 32: ...t MM Set Trajectory Slew Rate Generator Amps Sec or RPM Sec AL DL MM View MM Set Analog Input Scale MM Set 32768 IAS Mode 1 Current Command SVC Velocity Limiter VL MM View MM Set Mode 2 Velocity Comma...

Page 33: ...Velocity Control Loop Diagram Velocity Error MM Set MM Set MM Set Raw Velocity Estimate Proportional Gain MM Set 32768 GVP Integral Gain MM Set 32768 GVI Tach Gain MM Set 32768 GVF Derivative Gain MM...

Page 34: ...conversion Park Transform Station Frame to Rotation Frame conversion Incremental Encoder MM View Sensored Vector Current Control Loop Diagram Rotor Time Constant VFT MM Set Induction Motor GLENTEK cus...

Page 35: ......

Page 36: ...208 Standard Street El Segundo California 90245 USA Telephone 310 322 3026 Fax 310 322 7709 www glentek com e mail sales glentek com...

Reviews: