Page 26
INSTALLATION
INST
ALL
A
TION
‘A’ Class BoilerMate OV SOL issue4.ai
Bl
Bl
Bl
Bl
Bl
R
R
R
R
G/Y
Br
Br
Br
Br
Y
Br
Br
Br
Y
B
Y
B
Wh
Wh
G
Wh
Wh
Wh
R R
B
BL
Br
Bl
Bl
Bl
Br
Br
Br
B
B
B
Br
G/Y
G/Y
G/Y
R
O
O
B
B
Y
Y
S4
ID_RESIST
OR
S3
S1 & S2
Green Neon Illuminated
ON / OFF Switch
J33
J32
J28
J29
J3
L
L
L
N
N
N
E
E
E
M
M
M
* All wire sizes 0.5mm² unless otherwise stated
Y
White
Covering
(1) Connection only used
if Modulating Pump is fitted
(1)
('SWITCH' ON / OFF)
(Boiler ON / OFF)
(Heating SL-H)
(Hot Water SL-W)
(Frost Protection SL-F)
(Room Stat SL-R)
DHW
Pump
Heating
Pump
Boiler
Pump
1b
1a
1
O
I
1a
1b
1
Rocker Switch
terminal
conections
Zone Valve
B
A
Normally
Closed
Mod
3
Speed
3
Speed
Blue
Bl
Brown
Br
Green
Grey
Green / Yellow
G
Gr
G/Y
WIRE COLOUR LEGEND
Black
Orange
Yellow
White
Red
B
Or
Y
Y
Wh
R
S 3
S 4
S 5
S 6
Store overheat sensors
Cold Water IN
Domestic Hot Water OUT
Bottom store sensor
1K5 Resistor ID_Resistor (White)
Middle store sensor
S1 & S2
SENSOR LEGEND
Sc
Sz
Solar Collector sensor 20K
Dedicated Solar Zone 20K
Br
Br
O
O
Br
Wh
S5
S6
Br
Wh
Y
G
Br
Wh
R
Wh
Wh
R
J1
J9
J2
Status LED
Bl
Br
Br
Bl
Sr
S 7
Solar Return Temp 147DI
Solar Flow Rate 147DI
F
G/Y
Or
Wh
BL
J34
J5
J30
J31
J9
(1)
Br
Br
Br
MCB 2
MCB 1
MCB 3
16A
6A
16A
N
L
N
E
SL-W
SL-B
SL-R
L1
L2
L3
N
N
N
SL-F
N-IH
L-IH
L-IH
Bl
Bl
R
2 x 3kW Heating Elements
R
E
E
PE-IH
2.5 mm SID Silicone
2
4.0 mm Tri-Rated
2
2.5 mm SID Silicon
2
2.5 mm SID Silicone
2
4.0 mm SIF Silicone
2
2.5 mm SIF Silicone
2
2.5 mm SIF Silicone
2
2.5 mm SIF Silicone
2
2.5 mm SIF Silicone
2
Solar Collector Sensor fitted
in the panel sensor pocket
provided by manufacturer.
Minimum pocket size 8mm.
Solar Sensor cable will need to
be extented to reach the panel,
0.75mm two core flex and 5 amp
2 post junction box will be required
fitted in the roof space close
to the Solar panel sensor pocket.
Remove link to fit room stat.
3 WAY BUS BAR
SL-H
Dedicated Solar Zone Sensor fitted
in the pocket provided in the bottom
1/3 of the thermal store.
147MP_34
147SC-0-1
147DI_2
20K NTC
20K NTC
Sensor Body
Mains Supply
230VAC 50Hz 32Amps
6.0/10.0mm² Twin & Earth Cable PVC
(10.0mm² is only required when there is a high
ambiant temperature and/or long cable run)
CH1
HOT
WATER
CH2
CH
TWO CHANNEL DIGITAL CLOCK
1
2
3
4
5
L
~
3
1
2
8
7
6
5
4
A
B
C
D
E
DRG. NAME
DRG. SIZE
JOB NAME
TITLE
BOILERMATE 'A' Class OV SOL ADL1
With Gledhill Solar Controller
and two 2 port valves, factory fitted
2 channel digital clock.
Electrical Schematic for :
BOILERMATE 'A' class OV SOL
Appliance fitted with 2 channel digital clock
ISSUE No : 4
APPROVED
DATE : MARCH 2008
A3
GLEDHILL WATER STORAGE LTD.
DO NOT SCALE FROM THIS DRAWING. COPYRIGHT OF THIS DRAWING
IS RESERVED. IT IS NOT TO BE REPRODUCED COPIED OR DISCLOSED
TO A THIRD PARTY EITHER WHOLLY OR IN PART WITHOUT OUR
WRITTEN CONSENT.
© GLEDHILL WATER STORAGE LTD.
SYCAMORE TRADING ESTATE
SQUIRES GATE LANE
BLACKPOOL
LANCASHIRE
FY4 3RL
DRN.
SIGN.
DATE
DATE
APP'D.
CH'KD.
DATE
03-03-08
03-03-08
03-03-08
S. McGachie
S. Gataora
S. Gataroa
Zone Valve
B
A
Normally
Open
SIGN.
VAL-N
VL-N/O
VAL-SL
Sc
Sc
2
Sc Solar Panel Sensor
VAL-PE
2.5 mm SID Silicone
2
2.5 mm SID Silicone
2
C1
A1
A2
2
4
1
3
2.5 mm SID Silicone
2
2.5 mm SID Silicone
2
PE
Temperature signal
Flow signal
V
V
Pipe system
1
2
3
4
Pin numbers
UPR 15/50 Modulating Solar Pump
Sz
Sz
Sz Solar Zone Sensor
VL-N/C
J5
J6
J7a
J7b
J3
Additional Solar Add On Rail
BoilerMate OV Solar
Mode> Normal
N
L
2
3
4
1
ON
SPD1/2A
OPTIONAL EXTRA
IF FITTED
PART No.
XB142