Page 8
DESIGN
TECHNIC
AL DA
TA
Figure 1.4
B
E
C
BoilerMate A-Class
OV SOL
300
**
350
A
100
*350
D
F
Maintenance
access
*Minimum access /
maintenance access
above the appliance
case.
**To comply with the
access requirements of
the Water Regulations.
The minimum clear
opening in front of
the appliance to be
at least the same as
the depth of the
appliance
plus 50mm.
The cupboard door
opening will need to
take into account the
various sizes of
appliances.
F&E cistern
BMA 215-225 OV SOL
BMA 235-285 OV SOL
Appliance Dimensions
Model
Height
(A)
Width
(B)
Depth
(C)
BMA 215
OV SOL
1330
560
620
BMA 225
OV SOL
1330
560
620
BMA 235
OV SOL
1575
560
620
BMA 245
OV SOL
1575
610
690
BMA 265
OV SOL
1575
640
715
BMA 285
OV SOL
1485
710
785
The above dimensions do not include the
100mm high installation base.
Minimum Cupboard Dimensions
Model
Height
(D)
Width
(E)
Depth
(F)
BMA 215
OV SOL
2080
660
630
BMA 225
OV SOL
2080
660
630
BMA 235
OV SOL
2025
660
630
BMA 245
OV SOL
2025
710
700
BMA 265
OV SOL
2025
740
725
BMA 285
OV SOL
1935
810
795
The above dimensions include the 100mm
high installation base. In the case of the 215-
225 models, they assume the F&E cistern is in
the same cupboard. However, for the 235-285
models they allow space for installation/
maintenance of the appliance only.
Note: With the 235-285 models, space will
be required, in addition to the above, for two
feed and expansion cisterns (280mm wide x
420mm deep x 300 high), which are provided
separately, complete with a ballvalve and
overflow connector. 350mm will still be required
above the cisterns to meet the minimum access
requirementsof the Water Regulations for the
ballvalve.