Regular Cleaning 

Regular cleaning should be carried out, increasing the frequency if the area is subject to excess debris such as falling leaves or heavy 
soiling from atmospheric pollution

. Due to the Free Standing Skybox’s unique bonding method and the pitch built into th

e product, 

there should be no water ponding on the glass when installed correctly. 
 
Any standard glass cleaning product can be used to clean the glazing units. However, take care not to use abrasive materials or 
cleaners as this may affect the unit and its finish. The framework of the unit can be cleaned using warm soapy water with a soft lint 
free cloth. It is important to avoid getting water into the internal channels of the product framework. Therefore, Glazing Vision highly 
recommends carrying out any cleaning of the product whilst in the closed position. 
 

 

Clean the glass and inspect the integrity of the glazing units. 

 

Clean the frame and inspect the finish integrity. 

 

Clean and inspect all rubber/silicone seals, contact Glazing Vision to arrange for replacement seals to be fitted if required. 

 

Clear any debris from and around the unit. 

 

Clean the rain sensor (if present). 

 

Disposal at End of Life 

 
Glazing  Vision design products  with  ease  of  recyclability at  end  of  life  in mind. Many of the main  components  used are widely 
recyclable and we encourage you to recycle the unit and/or dispose of the component parts responsibly, in accordance with the 
guidance from your local authority.  
 
This product comprises the following materials: 
 

Aluminum framework and corner brackets 

Widely accepted for recycling at local recycling depots. 

Steel framework and corner brackets 

Widely accepted for recycling at local recycling depots. 

Stainless steel  
(Fixings, nuts, bolts, screws, brackets etc.) 

Widely accepted for recycling at local recycling depots. 

Glass 

Widely  accepted  for  recycling. Check  disposal  locations  with  your  local 
recycling depot. 

PVC/nylon/plastic 

Recyclable - check disposal with your local recycling depot. 

Rubber seals and silicone sealant 

Not currently recyclable. 

Electrical components 

If  your  unit  is  repaired  or  decommissioned  by  Glazing  Vision,  we  will 
remove  and  recycle  the  electrical  components  under  our  producer 
obligations.  Alternatively,  please  dispose  of  as  Waste  Electrical  and 
Electronic Equipment (WEEE) at your local recycling depot. 

Batteries 

If  your  unit  is  repaired  or  decommissioned  by  Glazing  Vision,  we  will 
remove  and  recycle  any  batteries  under  our  producer  obligations. 
Alternatively, please dispose of as segregated battery waste at your local 
recycling depot. 

 

 

 

Summary of Contents for Free Standing Skybox

Page 1: ...700 OM UK 001 v1 0 09 Jul 2020 www glazingvision co uk 44 0 1379 658300 info glazingvision co uk Free Standing Skybox...

Page 2: ...Section Description Page Introduction 3 Safety Information 4 Controls and Operation 6 Product Safety 9 Manual Override 9 Troubleshooting 11 Glass Specification and Breakage Instructions 12 Routine Tes...

Page 3: ...nal extras including a rain sensor thermostat remote control and Building Management System connectivity are available Proximity detection safety sensors that immediately stop the product moving when...

Page 4: ...ll be taken Overcurrent protection is designed to prevent damage to the product and its mechanisms It should not be relied upon to prevent injuries Let our experts carry out your routine maintenance w...

Page 5: ...ivating and cause injury Do not pull on the cables where they exit the product Doing so may loosen connections result in damage to the product and or create the need for a repair visit Do not leave th...

Page 6: ...ion releasing the switch stops the product in that position Note that the product will stop automatically when it becomes either fully open or closed Status Light The status light will illuminate gree...

Page 7: ...em The status light on the remote control should turn red for a few seconds and then turn off If it turns green or amber try pressing the three buttons again When the red status light turns off the re...

Page 8: ...but via a key operated switch In addition the key switch does offer press and hold operation To open the product turn the key in a clockwise direction To close the product turn the key in an anti clo...

Page 9: ...ding Skybox is stuck in the open or closed position and will not open close electrically the mechanisms can be disengaged to allow the lid to be opened closed manually Manual override can be done from...

Page 10: ...ch next push the open button on the control switch and run the mechanisms to approximately halfway open and stop them the mechanisms are concealed by brush strip which can be pushed aside to check the...

Page 11: ...nchronising The condition will clear automatically when the product has initialised Continuous amber Indicates that a proximity safety sensor has been triggered preventing the product from closing it...

Page 12: ...il the rain stops before trying to open the product If the rain sensor needs cleaning open the product and isolate the power supply then clean the rain sensor The thermostat if specified is reacting t...

Page 13: ...sumes Glazing Vision Engineers or Approved Installers installers that have attended a Glazing Vision Installation training course for this product and carry Approved Installer status or an experienced...

Page 14: ...rain sensor if present Disposal at End of Life Glazing Vision design products with ease of recyclability at end of life in mind Many of the main components used are widely recyclable and we encourage...

Page 15: ...the maintenance log section of this manual for future reference If you need to contact us for any reason Glazing Vision may ask for the product s serial number to enable us to assist with your enquir...

Page 16: ...ents yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement ye...

Page 17: ...cement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirement...

Reviews: