Routine Testing and Maintenance 

 

General Maintenance and Safety 

To keep the Free Standing Skybox in good working order there are a few basic points that should be observed: 

 

Do not place anything on, or cause obstruction to the moving section of the Free Standing Skybox when opening the unit 

as this may cause damage to the unit’s mechanisms and/or prevent

 it from opening. 

 

Do not walk or sit on the unit (except for the designated treadplate). 

 

Make sure that fingers and other obstructions are clear of the product and its mechanisms during any operation, severe 
damage/injury may be caused. 

 

Do not touch the motors/mechanisms after operating the unit as they may become hot. 

 

Do not remove the treadplate protecting the control board, as this may allow the controls to become damaged. 

 

Do  not  allow  unauthorised persons  (e.g. children)  to  operate the product  as  this  may  lead  to  injury or  damage  to  the 
product. 

 

Specific Maintenance Requirements  

Maintenance  must  only  be  carried  out  by  suitably  qualified  personnel*.  The  following  maintenance  requirements  must  be 
completed and logged on the sheets at the back of this manual. Glazing Vision can offer a service/maintenance contract 

 please 

contact us for further details. 
 
*Suitably  qualified  assumes  Glazing  Vision  Engineers  or  Approved  Installers  (installers  that  have  attended  a  Glazing  Vision 
Installation training course 

for this product and carry ‘Approved Installer’ status),

 or an  experienced electro-mechanical service 

engineer. 
 

Monthly Requirements 

 

The product should be fully opened and closed to ensure that the seals are free, and the mechanisms function evenly. 

 

Annual Requirements (at least annual - recommended every 6 months) 

 

Check the integrity of the glazing units (there should not be any misting or condensation). 

 

Check that all moving parts are free from debris. 

 

Grease (Shell Gadus s2 v220 2 or equivalent) the mechanism leadscrews. 

 

Lubricate (WD-40 Specialist High Performance Silicone Lubricant or equivalent) all other moving parts and check they move 
freely (may need to remove product flashings). 

 

Check that the mechanisms are straight and true. 

 

Check that the proximity sensors are clean, aligned, secure and undamaged. 

 

Check that all fixings are appropriately tightened. 

 

Check that access to the overrides is clear and advise the relevant party to amend if not. 

 

Check all electrical cables and ensure that they are not trapped and/or damaged. 

 

Check that no water is in the unit. 

 

Clean and inspect all rubber/silicone seals, contact Glazing Vision to arrange for replacement seals to be fitted if required. 

 

Check that electrical connections are well made and secure. 

 

Check that the control switch does not show any errors. 

 

Test the operation. 

 

Test any optional extras present. 

 

Every 5 Years 

 

Replace the backup batteries (if present). 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Free Standing Skybox

Page 1: ...700 OM UK 001 v1 0 09 Jul 2020 www glazingvision co uk 44 0 1379 658300 info glazingvision co uk Free Standing Skybox...

Page 2: ...Section Description Page Introduction 3 Safety Information 4 Controls and Operation 6 Product Safety 9 Manual Override 9 Troubleshooting 11 Glass Specification and Breakage Instructions 12 Routine Tes...

Page 3: ...nal extras including a rain sensor thermostat remote control and Building Management System connectivity are available Proximity detection safety sensors that immediately stop the product moving when...

Page 4: ...ll be taken Overcurrent protection is designed to prevent damage to the product and its mechanisms It should not be relied upon to prevent injuries Let our experts carry out your routine maintenance w...

Page 5: ...ivating and cause injury Do not pull on the cables where they exit the product Doing so may loosen connections result in damage to the product and or create the need for a repair visit Do not leave th...

Page 6: ...ion releasing the switch stops the product in that position Note that the product will stop automatically when it becomes either fully open or closed Status Light The status light will illuminate gree...

Page 7: ...em The status light on the remote control should turn red for a few seconds and then turn off If it turns green or amber try pressing the three buttons again When the red status light turns off the re...

Page 8: ...but via a key operated switch In addition the key switch does offer press and hold operation To open the product turn the key in a clockwise direction To close the product turn the key in an anti clo...

Page 9: ...ding Skybox is stuck in the open or closed position and will not open close electrically the mechanisms can be disengaged to allow the lid to be opened closed manually Manual override can be done from...

Page 10: ...ch next push the open button on the control switch and run the mechanisms to approximately halfway open and stop them the mechanisms are concealed by brush strip which can be pushed aside to check the...

Page 11: ...nchronising The condition will clear automatically when the product has initialised Continuous amber Indicates that a proximity safety sensor has been triggered preventing the product from closing it...

Page 12: ...il the rain stops before trying to open the product If the rain sensor needs cleaning open the product and isolate the power supply then clean the rain sensor The thermostat if specified is reacting t...

Page 13: ...sumes Glazing Vision Engineers or Approved Installers installers that have attended a Glazing Vision Installation training course for this product and carry Approved Installer status or an experienced...

Page 14: ...rain sensor if present Disposal at End of Life Glazing Vision design products with ease of recyclability at end of life in mind Many of the main components used are widely recyclable and we encourage...

Page 15: ...the maintenance log section of this manual for future reference If you need to contact us for any reason Glazing Vision may ask for the product s serial number to enable us to assist with your enquir...

Page 16: ...ents yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement ye...

Page 17: ...cement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirements yes no Annual Requirements yes no Battery Replacement yes no Cleaning Requirement...

Reviews: