23
22
Operation
Emergency closure / Restart
The motor drive is protected against overheating and ceases to function
if there is a danger of overload, for example if several opening and closing
manoeuvres have been carried out within a short time. Proper functioning
cannot be ensured again until the motor has cooled down sufficiently
(around 5 to 10 minutes).
The emergency closure function is not part of
normal use and should only be carried out in an emergency.
1
1.
Insert allen key
2.
Turn allen key around 180° to the
right and decouple drive
3.
Close sunshade manually
Unlock motor drive
Manual closure should preferably
be carried out by two people on the
supporting arm at the mast.
!
3
1.
Manually close sunshade completely
2.
Insert allen key
3.
Turn allen key around 180° to the left
and couple in the drive
4.
Remove allen key
5.
Check proper functioning using the
remote control
Restart
After restart, be sure to carry out
the function test to ensure proper
functioning.
!
2
1.
Use the remote control to move the
motor drive into the closed position
(end position)
Reset motor drive
Wait until the motor switches itself
off after reaching the stop position.
!
To control the functions, tap the buttons several times or keep them
pressed down.
The last setting will be saved
*
Touch
Controls
Press and hold
Direct light on / off*
brighter / darker
Indirect light on / off*
brighter / darker
Mast light on / off*
brighter / darker
brighter / darker
Without function
Open / stop / close / stop sunshade
All lights on / off
All off without saving >
saved light scenario on
save current lighting
scenario
1.3
1.2
3.1
3.3
Summary of Contents for Nova Pz200