15
2112-01
1075A
A
L. LARSON
1-26-05
2112-01
LABEL, TRANSFORMER
SIZE: (ref.): 4" X 4-1/4"
COLOR:
BORDER, LINES, AND TEXT - BLACK
BACKGROUND - WHITE
MATERIAL:
ADHESIVE-BACKED WHITE POLYESTER with CLEAR
POLYESTER LAMINATE ON THE TOP OF LABEL.
2.
Connect the supplied swivel fitting p/n 23825-00
to the trigger air line
before
attaching the hose
assembly to the gun.
30.
Connect hose assembly and the gun as
shown. The fittings on the hose assembly
are sized differently and will attach only one way.
31.
Fluid and air connections between the system and
gun should now be complete and
tight
.
When Main Power to system console is on, the white
and black wires in the console are
always live!
Disconnect or turn
off
Main Power source before
opening console to make any repairs or before making
any electrical repair of any type to the system.
If you do not understand the electrical hook-up
described above, consult your local GlasCraft distributor
OR a qualified electrician.
Electrical connections must be checked on a
periodic basis.
• 208/240 volt single phase
• L1 L2 GROUND
• 208/240 volt three phase
• L1 L2 L3 GROUND
• 380 volt three phase
• L1 (black)
• L2 (brown)
• L3 (black)
• L4 (blue)
• GROUND (green)
32.
If more than 50 ft. of hose is used the transformer tap
setting will need to be set for proper hose length. The
sticker on the front cover will say which tap to move
the wire to.
DO NOT MOVE THE COMMON LEG!
Section 1 - Installation: Equipment Assembly
Summary of Contents for GUARDIAN A6-6000
Page 25: ...23 REVISION E Section 3 General Information Assembly Drawings 23675 XX Unit Assembly...
Page 26: ...24 REVISION E Section 3 General Information Assembly Drawings 23675 XX Unit Assembly...
Page 32: ...Section 3 General Information Sub Assembly Drawings 30 REVISION D 23450 XX Hybrid Assembly...