7. Technical characteristics
1. NOMINAL POWER SUPPLY
230 V ac, 115 V ac or 24 V dc , depending on version, main and
emergency power supply with automaitc change-over, power supply
failure indication
2. MAX. CURRENT CONSUMPTION
(WITHOUT LIGHTS)
230 V ac version - 0.135 A max
115 V ac version - 0.27 A max
24 V dc version - 2 A max
3. MODULES’ CONSUMPTION
Main unit ITNSL-01TP : 19 V dc, 0.54 A max
Input module ITNL-10-D-230 : 19 V dc, 0.16 A max
Input module ITNL-5-D-230 : 19 V dc, 0.1 A max
Input module ITNL-10-S-230 : 19 V dc, 0.19 A max
Input module ITNL-13-S-230 : 19 V dc, 0.2 A max
Input module ITNL-10-D-24 : 24 V dc, 0.27 A max
Input module ITNL-5-D-24 : 24 V dc, 0.14 A max
Input module ITNL-10-S-24 : 24 V dc, 0.27 A max
Input module ITNL-13-S-24 : 24 V dc, 0.3 A max
4. MAXIMAL / POSSIBLE
CONFIGURATION
Up to 5 input modules (in total) can be installed
Up to 3 pcs. of ITNL-10-D or ITNL-5-D (double lights)
Up to 5 pcs. of ITNL-10-S or ITNL-13-S (single lights)
ITNL-10-D and ITNL-10-S can be combined in the same system
Maximum number of lights: 80 (in configuration 30 double lights
and 20 single lights)
6. LIGHTS’ POWER RANGE
4-100 W (230 V ac)
4-65 W (115 V ac)
4-40 W (24 V dc)
Flashing lights are allowed
7. INPUT MODULES POWER
RANGE
800 W (230 V ac)
430 W (24 V dc)
8. LIGHTS’ FUSES
5x20mm, each pole, mounted on input modules
9. LIGHTS’ TURN ON / OFF IN CASE
OF EMERGENCY
Manual activation of lights directly on input modules, power
supply
10. ALARM / SIGNALIZATION OUTPUT
SYSTEM OPERATING voltage-free C.O. contacts 250 V ac/1A,
for indicating that system is functioning correctly
COMMON ALARM voltage-free C.O. contacts 250 V ac/1A, for
broken light circuit alarm and power/system failure alarm
NMEA 0183 TRANSMITTER - $NLALR sentences for normal
state, alarm state, main and emergency supply alarms
11. LIGHTS’ CIRCUIT FAILURE ALARM
DELAY
2-6 s, automatic change-over to spare light (if exists)
12. EXTERNAL ALARM ACCEPT
INPUT
N.O. Voltage-free contact, quits buzzer only
NMEA 0183 receiver - $--ACK sentence for external audio alarm
acceptance, quits buzzer only
13. COMMUNICATIOS BETWEEN
MODULES
RS485, ITNL addresses configured via dip switch
14. LIGHTS’ CONFIGURATION AND
CONDITION
Presented on 7” TFT touch display
5. AVAILABLE INPUT MODULES
ITNL-10-D-XXX for 10 double lights*
ITNL-5-D-XXX for 5 double lights*
ITNL-10-S-XXX for 10 single lights**
ITNL-13-S-XXX for 13 single lights**
XXX -230 for 230/115 V AC light power supply
- 24 for 24 V DC light power supply
* can be used for single lights
** can be used for double lights, however each light uses 2 inputs
Summary of Contents for NL95
Page 1: ...Rev 4 Print date 2021 05 05 NL95 Touch Screen Navigational Light Controller NL95 User manual ...
Page 2: ...Rev 4 Print date 2021 05 05 NL95 ...
Page 42: ...Rev 4 Print date 2021 05 05 38 NL95 6 2 Configuration setup form ...
Page 51: ...Rev 4 Print date 2021 05 05 47 NL95 9 2 Configuration setup form ...