Rev.:
4
, Print date: 202
1
-
05
-
05
31
NL95
Main power supply OK
MAIN
MAIN
Main power supply ALARM
Emergency power supply OK
EMERG.
EMERG.
Emergency power supply ALARM
Power Supply module ITNSLP-01P communication OK
SYS
SYS
Power Supply module ITNSLP-01P module communication ALARM
NOTE:
In case that ITNSLP-01P module communication is in alarm,
power supply main and emergency indication will be unavailable
One or more light modules communication ALARM
For detailed status of modules and communication reset pls. enter system/status screen
MODULES
MODULES
Communication with light input modules OK
No module configured, or in configuration mode
MODULES
IMPORTANT!!!
REMOTE CONTROL ENABLED
- the system is controlled from remote location by
communication protocol. Local control of lights is unavailable, checking light status is possible.
Please check separate document for further information
LIGHTS
GROUPS
LIGHTS
CONFIGURATION ERROR
If system was not correctly switched off, i.e. power supply blackout, on next system start-up alarm type
"SHUTDOWN ALARM" will be initiated. Pls. check picture above.
IMPORTANT!!!
All lights that were switched on before shutdown will be restored automatically. Pls. check
if appropriate lights are switched on.
If
INVALID CONFIGURATION
is shown, this means that one or more lights are missing either
connection or position on mimic. Please check configuration section
MAIN
EMERG.
SYS MODULES
PS
SB
Summary of Contents for NL95
Page 1: ...Rev 4 Print date 2021 05 05 NL95 Touch Screen Navigational Light Controller NL95 User manual ...
Page 2: ...Rev 4 Print date 2021 05 05 NL95 ...
Page 42: ...Rev 4 Print date 2021 05 05 38 NL95 6 2 Configuration setup form ...
Page 51: ...Rev 4 Print date 2021 05 05 47 NL95 9 2 Configuration setup form ...