background image

GlammFire.  

 

 

                                                                                                                      PAG./35 

 

GlammFire  fireplaces  are  manufactured  under  the  strict  Standard  of  the  world  recognized  ISO  9001:2008  (TUV) 
Quality Assurance Certificate. 
GlammFire products are designed with superior components and materials, assembled by trained craftsmen who take 
great pride in their work.  
Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure 
that you, the customer, receive the quality product that you expect from GlammFire. 

Series and Guarantee numbers 

Distributor code 

Name and Address of the Distributor 

Equipment 

Guarantee beneficiary 

Version 

Address 

Controller 

Tel. 
Availability date 

Local…………………………………………..Date…………………….. 

 

Signature 

GlammFire is always concerned with the environment. This is reflected by the projection of their products and their 
packaging. Focusing on the reduction of energy consumption, raw materials, natural resources and quantity of waste 
generated,  GlammFire  follows  the  policy  of  the  4R's  (Reduce,  Reuse,  Recycle  and  Recover).  Thus  GlammFire  has  in 
mind the use of long lasting products as well as reusable and recyclable products.  
GlammFire  recommends  reusing  the  GlammFire’s  packaging  separately  and  deposit  plastic,  paper,  cardboard  and 
glass in the appropriate collection point.  
 

"In nature nothing is created, nothing is lost, everything is transformed." 

Antoine Laurent de Lavoisier 

Summary of Contents for Apollo EVO Plus

Page 1: ...INSTRUCTIONS MANUAL Crea7ionEVO PLUS WALL MOUNTED FIREPLACES ...

Page 2: ...GlammFire PAG 2 ...

Page 3: ...s 12 5 6 Levelling of combustion fire line 16 5 7 Home Automation Option 17 6 Operation 18 6 1 Functions Buttons 18 6 2 Language Selection 20 6 3 Remote Control synchronization 21 6 4 Turn on 21 6 5 Out of fuel 22 6 6 Turn off 23 6 7 Fuel reserve 23 6 8 Battery charging 24 7 Security Systems 24 7 1 Leak detection system 25 7 2 Vibration Sensor 25 7 3 Tank door locking system 25 7 4 Smothering the ...

Page 4: ...e frame Please read this Instructions Manual carefully before using your decorative fireplace It contains important operating and maintenance instructions that should be followed correctly in order to ensure a durable use of your decorative fireplace All presented cautions and warnings must be respected Keep this manual for future reference This Instruction Manual is subject to change without noti...

Page 5: ...unctioning of the fireplace Keep a regular watch during use of the fireplace Keep children and animals away from the fireplace Children do not recognize danger Therefore make sure children are kept at a safe distance Keep children watched when fireplace is working The fireplace should not be exposed to direct sunlight or any heat source as it may damage its materials If you spill bioethanol onto t...

Page 6: ...f this time the flame will extinguish naturally If bioethanol pours out during the process of filling up the tank clean the tank and surrounding area before using again Decorative stones wood or other accessories should not be placed directly on top of the burning area Should you use decorative accessories make sure The accessories do not interfere with the flame Are only for decorating the firepl...

Page 7: ...ntation and distillation of sugars from plants such as sugar cane potato beetroot and cereals The use of bioethanol guarantees a reduction of 85 in CO2 emissions therefore contributing for the reduction of global warming Use only liquid bioethanol as fuel Only bioethanol will make a clean and perfect combustion Keep bioethanol away from children and animals as well as from a working fireplace Avoi...

Page 8: ... to install the combustion fire must be as level as possible The model cannot be build in as its purpose is to hang on the wall surface always respecting the lower ventilation grid 5 1 Dimensions To access to the control panel and tank will be necessary to ensure a distance between the fireplace and potential obstacles on lateral sides superior to 300 mm A 300 mm GlammFire PAG 8 ...

Page 9: ...GlammFire PAG 9 5 2 Flammable materials Do not place flammable materials near the fireplace within 1 meter Bookcases or shelves should be spaced 1 meter away of the combustion line ...

Page 10: ...when unpacking your fireplace The decorative frame is seated in the wall fastening plate but it is loosened Separate the decorative frame to start the installation 5 3 Tools Required Drill Wrench Tape measure Pencil Spirit Level Phillips Screwdrivers 1 Fireplace body 2 Decorative frame 1 2 ...

Page 11: ... your fireplace is level Choose the type of fastener suitable for the wall material and proceed to the drilling Tighten the fireplace to the wall properly Check the stability and levelling Make adjustments if necessary A 6 Holes ø8 mm 1 Washer ø5 2 Nut M5 To complete the installation of your fireplace fit the decorative frame and tighten the nuts provided ...

Page 12: ...aterial Supplied 4 3 2 1 1 Screws 2 Protective black mirror tape 3 Mounting bracket 4 Black Mirror 5 5 2 Optional Black Mirror Installation Procedures Remove the decorative frame of the fireplace Inside the fireplace there are the specific holes A to make this opera A ...

Page 13: ...the mounting brackets using the screws supplied and do not forget to put the protective black mirror tapes B Place the black mirror inserting it into the upper mounting bracket When docked touch it inside the fireplace C C B ...

Page 14: ...GlammFire PAG 14 Let the black mirror slide slowly without dropping it to fit into the lower mounting bracket D Make all procedures very carefully so as not to damage the black mirror D ...

Page 15: ...GlammFire PAG 15 Finally proceed to the setting of the decorative frame E The installation of the fireplace is complete E ...

Page 16: ... flame does not occupy the entire opening it will be necessary to level the combustion fire line Lack of flame on the left Turn the screw F clockwise to clockwise Parallel turn the screw counter clockwise Lack of flame on the right side Turn the screw F clockwise to clockwise Parallel turn the right screw counter clockwise Repeat the procedure described until you get a uniform flame ...

Page 17: ...tion system unscrew the four screws from the technical box and remove the existing protective cover Figure 2 Sealed technical box with plug for home automation Figure 1 Identification box home automation connection Figure 2 Box opening to access home automation Note For the functionality of the home automation system the device must be switched on in standby mode receiving energy otherwise its fun...

Page 18: ...wiring To connect the electric wires slide easy connection of the burner plug insert the electric wire and release the connection Figure 3 Figure 3 Identification of connectors Note This functionality must be used with responsibility and supervision GlammFire is not responsible for incidents inherent to the connection to home automation On Off Comum ...

Page 19: ... supply source battery or electric current To do it select desired option using the ON OFF ON button as shown in Figure 4 Figure 4 ON OFF ON Button I Electric current O OFF without power supply II Battery I Turn on O Turn off I O two bips from Min to Max or vice versa Glamm Fire Display I O ...

Page 20: ...d and the Crea7ionEVO PLUS is ready to use Figure 5 Localization of the input Plug I Figure 6 Hole outlet for the AC adapter If you want to use the system connected to the battery you must select the II option If you want to use the system connected to the electric current you must select the I option If you use the Crea7ionEVO PLUS system connected to the electric current do not forget to connect...

Page 21: ...m is ready to start lighting 6 Ref Ramp 7 Ignition 8 Maximum Minimum combustion level The Crea7ionEVO PLUS is always working at the maximum position If you want that it works at the minimum level you must click on the button on the remote control or at the same time the position I O on the display 6 3 Remote Control synchronization The synchronization of the remote control can only be achieved wit...

Page 22: ... In the tank zone In the tank lights up the flashing red light indicating the lack of bioethanol Then open the tank and fill it up 7 1 beep Steady red light minimum level reached 8 1 beep Steady yellow light medium level reached 9 1 long beep Steady green light maximum level reached On the display When getting the maximum level the following information appears on the display 10 Close the door 11 ...

Page 23: ... 6 7 Fuel reserve If the bioethanol runs out when the system is running 3 beeps will be heard followed by 2 beeps indicating that the system is switched off and the following information will be seen on the display 1 Tank Empty 2 Refill Tank The system is in error mode emitting consecutive beeps Clicking on the OFF button on the display you can check the error occurred Then the following informati...

Page 24: ...harge After recharging the battery you can assem ble it in the system following the same process in reverse Figure 7 System battery connector location Figure 8 Connect the battery connector to the char ger 7 Security Systems Whenever there is some kind of error it appears on the display Simultaneously the system emits one continuous beep The error remains on the display until you click on the OFF ...

Page 25: ... an accidental shock occurs It activates itself turning OFF the Crea7ionEVO PLUS when the device suffers an external shock during operation If it happens the following information will appear on the display 1 Error Vibrat To remove this error please click on the OFF button O on the display You can only remove this error when the external vibration ends 7 3 Tank door locking system The system does ...

Page 26: ...intenance Removal of tank is strictly prohibited while filling up To clean the filter you should open the fuel cap open the tank and remove the filter with your finger Then remove the impurities in it and put it back in the tank The use of Crea7ionEVO PLUS without this filter is never recommended because it can cause serious damage to the system Fuel Cap Tank Filter Figure 9 Local Tank filter loca...

Page 27: ...oor was unlocked by the servo motor The system is at the ideal tem perature You can now access the tank Low Bat Low battery warning Change the battery for the second battery supplied which should be properly recharged and recharge the battery removed Bt The system indicates the battery charge status If you do not want to use the sys tem turn it off using the ON OFF ON button in order to save en er...

Page 28: ...he transformer Otherwise you risk filling the tank causing over flowing as you will not get an indication of the filling level of the tank Tank OK Bioethanol level is at least at the minimum level steady red light The system checked that there is sufficient fuel in the tank to be put into operation and will pro ceed with lighting Close the door The tank door is open Close the tank door Error Incl ...

Page 29: ...ance has been switched off Do normal start up of the system following the usual instructions shown on the display Maximum The system is at the maximum level of combustion Let the Crea7ionEVO PLUS work normally Minimum The system is at the minimum level of combustion Let the Crea7ionEVO PLUS work normally Leakage Leak detected in the combustion fire line or system safety box The system turns off im...

Page 30: ...e combustion fire line Please always contact a qualified technician Doorlock Error The tank door was opened im properly damaged The tank door was damaged Do not turn on the Crea7ionEVO PLUS Please always contact a qualified technician Ignition When the resistance is incandes cent the system is igniting bio ethanol Let the Crea7ionEVO PLUS work normally Error Incl Vib The Crea7ionEVO PLUS is not le...

Page 31: ...hearing a bip Restart the Crea7ionEVO PLUS ETHANOL EXCEDED Too much bioethanol was de tected in the combustion line dur ing operation Please contact a qualified techni cian Error Sens Ethn Exc Short circuit sensor excessive level Please contact a qualified techni cian No display informa tion appears Excessive temperature Lack of battery No electrical connection Check ventilation It may be insuf fi...

Page 32: ...rasive sponges The surface can be scratched by them The manufacturer is not liable for any damage arising from misuse and or fraudulent of the product The manufac turer also can not be blamed for the failure to observe the cleaning or application instructions and or use of any other cleaning techniques Note Failure to follow the above rules eliminates any factory warranty on all models or fireplac...

Page 33: ...5 kW 6 h 1 32gal 198lb 29 m2 1450mm 650 mm 223 mm 90 kg 5l Mito Gene sis EVO Plus 57 09 25 60 8 00 4 5 kW 6 h 1 32gal 176lb 29 m2 1450mm 650 mm 203 mm 80 kg 5l Apollo IV EVO Plus 64 10 34 26 9 57 4 5 kW 6 h 1 32gal 243lb 29 m2 1628 mm 870 mm 243 mm 110 kg 5l Mito Small Genesis EVO Plus 39 38 25 60 8 00 2 kW 8 h 0 79gal 128lb 14 m2 1000 mm 650 mm 203 mm 58 kg 3l Mito Small EVO Plus 39 38 25 60 8 78...

Page 34: ...eces will be replaced free of charge if it is proved any de fect of manufacture Regarding defective pieces they will be sent free of charge and their switch is responsibility of the retailer responsible for the purchase of the appliance Our warranty is offered as an addition to your statutory rights It is applicable to the original purchaser only non transferable All repairs must only be fitted by...

Page 35: ...or Equipment Guarantee beneficiary Version Address Controller Tel Availability date Local Date Signature GlammFire is always concerned with the environment This is reflected by the projection of their products and their packaging Focusing on the reduction of energy consumption raw materials natural resources and quantity of waste generated GlammFire follows the policy of the 4R s Reduce Reuse Recy...

Page 36: ...PT08258 B Recuperadores Pachinha Lda Zona Industrial da Lagoa Lote G1 4950 850 CORTES MONÇÃO PORTUGAL Tel 351 251 654 800 Fax 351 251 654 801 info glammfire com www glammfire com ...

Reviews: