GlammFire.
PAG./29
INFORMATION
DISPLAYED
CAUSE
PROCEDURE
Time Exc
Sens Max
Lack of bioethanol in the combus-
tion line;
Maximum level probe with anom-
aly;
Tubing clogged with anomaly.
Fault in the ethanol supply pump.
Contact a specialist.
Ign. Time
Exceeded
Exceeded the time of ignition.
The ignition started late and the
temperature sensor did not have
time to analyze the temperature
rise.
Check if the resistance is incan-
descent. If not, it means that
there may be a problem with it.
Restart the system again, follow-
ing the usual instructions shown
on the display.
If the error appears again, please
contact a qualified technician.
Fire off
The appliance has been switched
off.
Do normal start-up of the system,
following the usual instructions
shown on the display.
Maximum
The system is at the maximum
level of combustion.
Let the Crea7ionEVO PLUS work
normally.
Minimum
The system is at the minimum
level of combustion.
Let the Crea7ionEVO PLUS work
normally.
Leakage
Leak detected in the combustion
fire line or system safety box.
The system turns off immediately.
Do not turn on the system.
Please always contact a qualified
technician.
Ethanol
High lev
Bioethanol maximum level detec-
tion in the combustion fire line
while the system is not running.
The fire was extinguished while
the system is running. (something
smothers the fire).
Bioethanol spillage when system
is off.
The system turns off immediately.
Let bioethanol burn in the com-
bustion fire line by making a man-
ual ignition using a lighter.