Press
to quit configuration and go
back to the position display
2 0 0.0
Parameter 12
– SETTING OF NEGATIVE INERTIA VALUE
The negative inertia value is the value of the system inertia at low speed, in negative
direction. If automatic inertia calculation is enabled (see parameter 20), the value is
updated automatically.
Example of value setting = 1.0 mm
P 12
Press
to select the parameter
(see PARAM. SELECTION)
0.0
P 12
Press
to confirm the selection and
enter its settings
0 0 0 0 0.0*
Enter the desired value and align it to the decimal point displayed.
P 12
Press
to confirm the value and go back
to parameters selection
1.0
Press
to quit configuration and go back
to the position display
2 0 0.0
Parameter 13
– SETTING OF POSITIVE INERTIA VALUE
The positive inertia value is the value of the system inertia at low speed, in positive
direction. If automatic inertia calculation is enabled (see parameter 20), the value is
updated automatically.
Example of value setting = 1.0 mm
P 13
Press
to select the parameter
(see PARAM. SELECTION)
0.0
P 13
Press
to confirm the selection and
enter its settings
0 0 0 0 0.0*
Enter the desired value and align it to the decimal point displayed.
P 13
Press
to confirm the value and go back
to parameters selection
1.0