Gira 5423 00 Operating Instructions Manual Download Page 7

Settings, channel

Parameters

Setting options, Basic
setting

Explanations

Manual commissioning

On, Off
Basic setting: On

Blocks manual commissioning
for the device channel. In the
"Off" setting, the device
cannot be reset to the factory
setting.

Operating mode

Switching
Buttons
Flashing
Continuous on
Continuous off
Basic setting: Switching

Switching
After switch-on, the device
remains stable in the "On"
state, and stable in the "Off"
state after switch-off.

Buttons
The device switches "On"
when any channel button of a
radio transmitter is pressed
and "Off" when the button is
released. It is irrelevant
whether the "On" or "Off"
channel button is pressed.

Flashing
Switch-on starts flashing and
switch-off stops flashing. The
default flash frequency is 1
Hz. This frequency is also the
maximum flash frequency.
The flash frequency can be
changed using parameters.
The parameter "Switch-off
delay" is used for the pulse
time and the parameter
"Switch-on delay" for the
pause time.

Continuous on
The output switches to
continuously "On". All
operations of radio
transmitters and the 

Prog

button are ignored.

Continuous off
The output switches to
continuously "Off". All
operations of radio
transmitters and the 

Prog

button are ignored.

Local Operation

On, Off
Basic setting: On

Blocks the output for operation
using the 

Prog

 button.

32581212

10499450

09.05.2016

7/11

eNet

Wireless switching/momentary-contact actuator, 1-gang Mini, Wireless
switching/momentary-contact actuator, 1-gang Mini, zero-voltage

Summary of Contents for 5423 00

Page 1: ...gerous voltage to the device or load Danger of electric shock Device is not suitable for disconnection from supply voltage Danger of electric shock on the SELV PELV installation Not suitable for switc...

Page 2: ...sible Switchable output with Prog button Status indicator via LED Switching mode of operation Switch on telegram Device switches on Switch off telegram Device switches off Operating mode buttons Relay...

Page 3: ...trical connection DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before carrying out work on the device or load disengage all the corresponding circuit breakers Cov...

Page 4: ...ion Function PC Operating mode and parameter set with eNet server M Operating mode buttons K Switching mode of operation If the operating mode switch is turned from the position PC to another operatin...

Page 5: ...actuator or radio transmitter are occupied i All On and All Off buttons of a radio transmitter are connected to the actuator automatically as soon as the first connection to the radio transmitter tak...

Page 6: ...onnection single stranded 0 75 4 mm Finely stranded with conductor sleeve 0 75 2 5 mm Dimensions H 53 28 mm Radio frequency 868 0 868 6 MHz Transmission capacity max 20 mW Transmitting range in free f...

Page 7: ...essed Flashing Switch on starts flashing and switch off stops flashing The default flash frequency is 1 Hz This frequency is also the maximum flash frequency The flash frequency can be changed using p...

Page 8: ...ot yet been switched off due to the delay when a switch on command comes then the load will remain on In Flashing operating mode the pulse times are set using this parameter Comment The set times appl...

Page 9: ...ing the switch off warning a switch on telegram effects direct switch on It is not possible to terminate the time using a switch off telegram Priority lock out protection 0 4 Basic setting 1 Specifies...

Page 10: ...on Minimum switching repeat time 100 ms 10 sec Basic setting 100 ms Limits the switching speed of the device by increasing the value in order to protect the load for example Only when the set time has...

Page 11: ...ira de konformitaet 6 5 Warranty The warranty follows about the specialty store in between the legal framework as provided for by law Please submit or send faulty devices postage paid together with an...