Settings, channel
Parameters
Setting options, Basic
setting
Explanations
Manual commissioning
On, Off
Basic setting: On
Blocks manual commissioning
for the device channel. In the
"Off" setting, the device
cannot be reset to the factory
setting.
Operating mode
Switching
Buttons
Flashing
Continuous on
Continuous off
Basic setting: Switching
Switching
After switch-on, the device
remains stable in the "On"
state, and stable in the "Off"
state after switch-off.
Buttons
The device switches "On"
when any channel button of a
radio transmitter is pressed
and "Off" when the button is
released. It is irrelevant
whether the "On" or "Off"
channel button is pressed.
Flashing
Switch-on starts flashing and
switch-off stops flashing. The
default flash frequency is 1
Hz. This frequency is also the
maximum flash frequency.
The flash frequency can be
changed using parameters.
The parameter "Switch-off
delay" is used for the pulse
time and the parameter
"Switch-on delay" for the
pause time.
Continuous on
The output switches to
continuously "On". All
operations of radio
transmitters and the
Prog
button are ignored.
Continuous off
The output switches to
continuously "Off". All
operations of radio
transmitters and the
Prog
button are ignored.
Local Operation
On, Off
Basic setting: On
Blocks the output for operation
using the
Prog
button.
32581212
10499450
09.05.2016
7/11
eNet
Wireless switching/momentary-contact actuator, 1-gang Mini, Wireless