Gira 5423 00 Operating Instructions Manual Download Page 3

i

The parameter list is on the Internet in the online instructions for this device.

Supplementary functions with eNet server:
-

Update of the device software

-

Repeater function

-

Reading of error memory

Behaviour after mains voltage return

The response after mains voltage return can be configured with the eNet server. Default setting:
Off.

4 Operation

Operation is with radio transmitters, please observe the radio transmitter instructions.

5 Information for electrically skilled persons

5.1 Fitting and electrical connection

DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.

Mounting and connecting actuator

To ensure good transmission quality, keep a sufficient distance from any possible sources of
interference, e.g. metallic surfaces, microwave ovens, hi-fi and TV systems, ballasts or
transformers. 

Figure 3: Connection example radio actuator/push-button actuator

32581212

10499450

09.05.2016

3/11

eNet

Wireless switching/momentary-contact actuator, 1-gang Mini, Wireless
switching/momentary-contact actuator, 1-gang Mini, zero-voltage

Summary of Contents for 5423 00

Page 1: ...gerous voltage to the device or load Danger of electric shock Device is not suitable for disconnection from supply voltage Danger of electric shock on the SELV PELV installation Not suitable for switc...

Page 2: ...sible Switchable output with Prog button Status indicator via LED Switching mode of operation Switch on telegram Device switches on Switch off telegram Device switches off Operating mode buttons Relay...

Page 3: ...trical connection DANGER Electrical shock when live parts are touched Electrical shocks can be fatal Before carrying out work on the device or load disengage all the corresponding circuit breakers Cov...

Page 4: ...ion Function PC Operating mode and parameter set with eNet server M Operating mode buttons K Switching mode of operation If the operating mode switch is turned from the position PC to another operatin...

Page 5: ...actuator or radio transmitter are occupied i All On and All Off buttons of a radio transmitter are connected to the actuator automatically as soon as the first connection to the radio transmitter tak...

Page 6: ...onnection single stranded 0 75 4 mm Finely stranded with conductor sleeve 0 75 2 5 mm Dimensions H 53 28 mm Radio frequency 868 0 868 6 MHz Transmission capacity max 20 mW Transmitting range in free f...

Page 7: ...essed Flashing Switch on starts flashing and switch off stops flashing The default flash frequency is 1 Hz This frequency is also the maximum flash frequency The flash frequency can be changed using p...

Page 8: ...ot yet been switched off due to the delay when a switch on command comes then the load will remain on In Flashing operating mode the pulse times are set using this parameter Comment The set times appl...

Page 9: ...ing the switch off warning a switch on telegram effects direct switch on It is not possible to terminate the time using a switch off telegram Priority lock out protection 0 4 Basic setting 1 Specifies...

Page 10: ...on Minimum switching repeat time 100 ms 10 sec Basic setting 100 ms Limits the switching speed of the device by increasing the value in order to protect the load for example Only when the set time has...

Page 11: ...ira de konformitaet 6 5 Warranty The warranty follows about the specialty store in between the legal framework as provided for by law Please submit or send faulty devices postage paid together with an...

Reviews: