Figure 4: Connection example radio actuator/push-button actuator potential-free
o
Connect load as shown in the connection example (Figure 3) or (Figure 4).
o
If multiple miniature circuit breakers supply dangerous voltages to the device or load,
couple the miniature circuit breakers or label them with a warning, to ensure disconnection
is guaranteed.
o
Insert the actuator in the appliance box in such a way that the
Prog
button and status-LED
are visible.
Figure 5: Operating mode switch
Switch position
Function
PC
Operating mode and parameter set with eNet
server.*)
M
Operating mode buttons
K
Switching mode of operation
*)
If the operating mode switch is turned from the position
PC
to another operating mode, the
parameters are set to the default setting. The settings made with the eNet server will be
lost.
o
Set the operating mode switch.
o
Switch on mains voltage.
i
The load can be switched by briefly pressing the
Prog
button.
Status-LED lights up: output switched on
Status-LED off: output switched off
o
Perform commissioning.